Part Details | FLUID FILTER
1650-00-764-4694 A filter having inlet and outlet connections and designed to be connected in a pipe, tube or hose line. For spin-on, base-mounted filtering devices with integral outer casings, see FILTER ELEMENT, FLUID. Excludes AIR CONDITIONER.
Alternate Parts: M881524, M8815/24, MILF881524, MIL-F-8815/24, 10106069, AC9416F16L, AC9416F16, AC9416F16Y1, AC9416F-16Y1, 7586589, 1650-00-764-4694, 00-764-4694, 1650007644694, 007644694
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 16 | OCT 07, 1972 | 00-764-4694 | 32622 ( FILTER, FLUID ) |
REFERENCE DRAWINGS & PICTURES
Y STRAINER W/THREADED COVER
Cross Reference | NSN 1650-00-764-4694
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| M8815/24 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-F-8815/24 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| 10106069 | A486G | NIMIKKEISTOKESKUS NCB FINLAND |
| AC9416F16L | 18350 | PALL AEROPOWER CORPORATION |
| AC9416F16 | 18350 | PALL AEROPOWER CORPORATION |
| AC9416F-16Y1 | 18350 | PALL AEROPOWER CORPORATION |
| 7586589 | 05228 | PTI TECHNOLOGIES INC. |
Technical Data | NSN 1650-00-764-4694
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 2 Y STRAINER W/THREADED COVER |
| BODY LENGTH | 2.750 INCHES NOMINAL |
| BODY WIDTH | 1.812 INCHES NOMINAL |
| BODY HEIGHT | 7.660 INCHES NOMINAL |
| DISTANCE FROM BOTTOM OF BODY TO CENTER OF INLET | 5.485 INCHES NOMINAL |
| DESIGN TYPE | NONREUSABLE |
| FILTERING ELEMENT QUANTITY | 1 |
| FILTRATION RATING IN MICRONS | 5.0 ABSOLUTE |
| MEDIA FOR WHICH DESIGNED | Y ANY ACCEPTABLE |
| MAXIMUM OPERATING PRESSURE | 3000.0 POUNDS PER SQUARE INCH |
| TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
| DROP PRESSURE | 10.0 POUNDS PER SQUARE INCH |
| FIRST INTAKE THREAD SERIES DESIGNATOR | UNJF |
| FIRST INTAKE NOMINAL THREAD SIZE | 0.437 INCHES |
| FIRST INTAKE THREAD CLASS | 3B |
| FIRST INTAKE THREAD DIRECTION | RIGHT-HAND |
| FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | IDENTICAL TO FIRST INTAKE CONNECTION |
| FILTERING SYSTEM FOR WHICH DESIGNED | FULL FLOW |
| FEATURES PROVIDED | DIFFERENTIAL PRESSURE INDICATOR |