Part Details | FLUID FILTER
1650-00-930-6123 A filter having inlet and outlet connections and designed to be connected in a pipe, tube or hose line. For spin-on, base-mounted filtering devices with integral outer casings, see FILTER ELEMENT, FLUID. Excludes AIR CONDITIONER.
Alternate Parts: AC76654, AC7665-4, 114HS12011, 114HS120-11, 114HS12011, 114HS120-11, 1650-00-930-6123, 00-930-6123, 1650009306123, 009306123
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 16 | JUN 22, 1966 | 00-930-6123 | 32622 ( FILTER, FLUID ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 1650-00-930-6123
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| AC7665-4 | 18350 | PALL AEROPOWER CORPORATION |
| 114HS120-11 | 77272 | THE BOEING COMPANYDBA BOEING |
| 114HS120-11 | 81996 | U S ARMY AVIATION AND MISSILECOMMAND |
Technical Data | NSN 1650-00-930-6123
| Characteristic | Specifications |
|---|---|
| BODY LENGTH | 4.680 INCHES NOMINAL |
| BODY WIDTH | 2.000 INCHES NOMINAL |
| BODY HEIGHT | 2.540 INCHES MINIMUM AND 2.560 INCHES MAXIMUM |
| DESIGN TYPE | REUSABLE |
| FILTERING ELEMENT QUANTITY | 1 |
| FILTRATION RATING IN MICRONS | 25.0 ABSOLUTE AND 10.00 NOMINAL |
| MAXIMUM OPERATING PRESSURE | 4500.0 POUNDS PER SQUARE INCH |
| FIRST INTAKE THREAD SERIES DESIGNATOR | UNF |
| FIRST INTAKE NOMINAL THREAD SIZE | 0.562 INCHES |
| FIRST INTAKE THREAD QUANTITY PER INCH | 18 |
| FIRST INTAKE THREAD DIRECTION | RIGHT-HAND |
| FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | IDENTICAL TO FIRST INTAKE CONNECTION |
| REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY SOURCE CONTROL DWG 114HS120 |
| FSC APPLICATION DATA | HYDRAULIC INSTALLATION,ACFT |