Part Details | LIQUID OXYGEN CONVERTER
1660-00-540-4645 A unit consisting of a jacketed container, with or without a heat source, used to convert liquid oxygen into gasous breathing oxygen. See also CONVERTER, LIQUID OXYGEN PUMPING METHOD.
Alternate Parts: 8148650, 290081C1, 29008-1C1, 1660-00-540-4645, 00-540-4645, 1660005404645, 005404645
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 16 | JAN 01, 1963 | 00-540-4645 | 12942 ( CONVERTER, LIQUID OXYGEN ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 1660-00-540-4645
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 8148650 | 98748 | AIR FORCE UNITED STATES DEPARTMENTOF THE |
| 29008-1C1 | 99251 | CARLETON LIFE SUPPORT SYSTEMS INC.DBA COBHAM MISSION SYSTEM |
Technical Data | NSN 1660-00-540-4645
| Characteristic | Specifications |
|---|---|
| GENERAL CHARACTERISTICS ITEM DESCRIPTION | 300 PSI,OPERATING PRESSURE; WARMING COIL METHOD OF OXYGEN WARMING; 80 L PER MIN,OUTPUT CAPACITY; W/PRESSURE CLOSING VALVE; 2 RELIEF VALVES; W/CHECK VALVE; W/O PRESSURE GAGE; W/O CAPACITANCE GAGING ELEMENT; BASE MTG; O/A DIM.,16.000 IN. LG,15.000 IN. W,20.250 IN. DEEP; W/O SPARE PARTS |
| NONDEFINITIVE SPEC/STD DATA | A-2 TYPE |