NSN 1660-01-372-2339

Part Details | AIRCRAFT HEATER

1660-01-372-2339 A heater used to raise the temperature of the air in the interior of aircraft in which it is installed. Circulation of the heated air may be achieved by an integral blower or fan. Excludes HEATER PACKAGE, AIRCRAFT, external type heaters, and portable type heaters.

Alternate Parts: 64993447731, 6499-344773-1, M2971K5003, M2971K500-3, 64993447731, 6499-344773-1, 64993447731, 6499-344773-1, 1660-01-372-2339, 01-372-2339, 1660013722339, 013722339

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
16MAR 04, 199301-372-233904712 ( HEATER, AIRCRAFT )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 1660-01-372-2339
Part Number Cage Code Manufacturer
6499-344773-118965DYNAMIC AIR ENGINEERING, INC.
M2971K500-318965DYNAMIC AIR ENGINEERING, INC.
6499-344773-180070LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
6499-344773-104614TEXTRON SYSTEMS CORPORATIONDBA TEXTRON DEFENSE SYSTEMS
Technical Data | NSN 1660-01-372-2339
Characteristic Specifications
HEAT DELIVERY RATE1200.0 BRITISH THERMAL UNIT
CURRENT TYPE AC
VOLTAGE IN VOLTS208.0
FREQUENCY IN HERTZ60.0
PHASE THREE
CURRENT RATING IN AMPS2.8
HEATING ELEMENT TYPE ELECTRIC NONIMMERSION
HEAT MEDIUM TYPE AIR
MOUNTING TYPE VENTILATION DUCT
HEIGHT6.480 INCHES MAXIMUM
WIDTH7.560 INCHES MINIMUM AND 7.680 INCHES MAXIMUM
DIAMETER2.780 INCHES NOMINAL
HEAT OUTLET QUANTITY1
HEAT DELIVERY DIRECTION HORIZONTAL
HEAT DISCHARGE OUTLET TYPE STATIONARY
HEAT DIRECTING DEVICE FLEXIBLE DUCTS
AIR CIRCULATION DEVICE PROPELLER FAN
QUANTITY1
SPEED ADJUSTMENTS SINGLE SPEED
MAXIMUM AIR FLOW RATE20.0 CUBIC FEET PER MINUTE
PRIME MOVER TYPE ELECTRIC MOTOR
CIRCULATED AIR TYPE HEATED
RADIO INTERFERENCE SUPPRESSION TYPE ANY ACCEPTABLE
OPERATING CONTROL TYPE
TEST DATA DOCUMENT96906-MIL-STD-454 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.).