Part Details | UPRIGHT DRILLING MACHINE
3413-00-222-2142 A drilling machine with vertical single or multiple spindle(s).
Alternate Parts: 2B8, 3413-00-222-2142, 00-222-2142, 3413002222142, 002222142
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
34 | JAN 01, 1963 | 00-222-2142 | 03945 ( DRILLING MACHINE, UPRIGHT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 3413-00-222-2142
Part Number | Cage Code | Manufacturer |
---|---|---|
2B8 | 19519 | NEW MONARCH MACHINE TOOL, INC.DBA MONARCH MACHINE TOOL |
Technical Data | NSN 3413-00-222-2142
Characteristic | Specifications |
---|---|
MOUNTING TYPE | FLOOR |
COLUMN TYPE | ROUND |
DRILLING CAPABILITY | 3/4 IN. IN MILD STEEL,7/8 IN. IN CAST IRON |
SPINDLE QUANTITY | 1 |
SPINDLE TYPE | TAPERED SOCKET |
SPINDLE TRAVEL DISTANCE | 7.500 INCHES NOMINAL |
DISTANCE FROM SPINDLE CENTER TO COLUMN | 8.000 INCHES NOMINAL |
SPINDLE SPEED QUANTITY | 4 |
SPINDLE SPEED RANGE IN RPM | P425.000/P1780.000 |
FEED TYPE | HAND |
HEAD TYPE | SLIDING |
HEAD VERTICAL ADJUSTMENT | 8.500 INCHES NOMINAL |
BASE WORKING SURFACE TYPE | SLOTTED |
BASE WORKING SURFACE SHAPE | ROUND |
BASE WORKING SURFACE LENGTH | 16.000 INCHES NOMINAL |
BASE WORKING SURFACE WIDTH | 14.625 INCHES NOMINAL |
BASE WORKING SURFACE MOUNTING LOCATION | BASE |
MAXIMUM DISTANCE FROM CHUCK/SPINDLE NOSE TO BASE WORKING SURFACE | 45.000 INCHES |
UPPER WORKING SURFACE TYPE | SLOTTED |
UPPER WORKING SURFACE SHAPE | ROUND |
UPPER WORKING SURFACE DIAMETER | 24.000 INCHES NOMINAL |
UPPER WORKING SURFACE ADJUSTMENT FEATURE | INCLUDED |
UPPER WORKING SURFACE VERTICAL ADJUSTMENT | 17.000 INCHES NOMINAL |
SWIVEL ADJUSTMENT IN DEG | 180.000 |
UPPER WORKING SURFACE MOUNTING LOCATION | COLUMN |
MAXIMUM DISTANCE FROM CHUCK/SPINDLE NOSE TO UPPER WORKING SURFACE | 30.000 INCHES |
MAIN DRIVE TYPE | ELECTRIC MOTOR |
ELECTRIC MOTOR POWER RATING | 1.000 HORSEPOWER |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | B220.0$B440.0 |
FREQUENCY IN HERTZ | 60.000 |
PHASE | SINGLE |
ROTATION REVERSIBILITY FEATURE | NOT INCLUDED |
RADIO INTERFERENCE SHIELDING | NOT PROVIDED |
FUNGUS RESISTANT TREATMENT | NOT INCLUDED |