Part Details | ELECTRIC HEAT TREATING FURNACE
3424-00-044-2754 Excludes induction heating.
Alternate Parts: 342412123440, 3424-1212-3440, LTE1248, LTE12-48, 3424-00-044-2754, 00-044-2754, 3424000442754, 000442754
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
34 | MAY 06, 1967 | 00-044-2754 | 06243 ( FURNACE, HEAT TREATING, ELECTRIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 3424-00-044-2754
Part Number | Cage Code | Manufacturer |
---|---|---|
3424-1212-3440 | 99998 | DEFENSE SUPPLY CENTER RICHMONDINDUSTRIAL PLANT EQUIPMENT /DLA/ |
LTE12-48 | 72419 | GENERAL SIGNAL CORP LINDBERG UNIT |
Technical Data | NSN 3424-00-044-2754
Characteristic | Specifications |
---|---|
DESIGN TYPE | ANY ACCEPTABLE |
MOUNTING TYPE | FLOOR |
WATTAGE RATING IN KILOWATTS | 54.0 |
MAXIMUM OPERATING TEMP | 1250.0 DEG FAHRENHEIT |
TEMP CONTROL DEVICE TYPE | AUTOMATIC |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | 460.0 |
PHASE | THREE |
INSIDE LENGTH | 36.000 INCHES NOMINAL |
INSIDE WIDTH | 48.000 INCHES NOMINAL |
INSIDE HEIGHT | 48.000 INCHES NOMINAL |
TILTING HEARTH | NOT INCLUDED |
WORK HOLDING BASKET | NOT INCLUDED |
COUNTERWEIGHT | NOT INCLUDED |
EQUIPMENT FOR FLAME CURTAIN | NOT INCLUDED |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | BOX TYPE,FLOOR MTD,AUTOMATIC TEMP CONTROL,NATURAL ATMOSPHERE,1250 DEG F MAX OPERATING TEMP,48 IN. W BY 36 IN. LG BY 48 IN. H WORK SPACE DIM.,460V,60 HZ,3 PHASE,54 KW HEATER ELECTRICAL DATA |