Part Details | ELECTRIC HEAT TREATING FURNACE
3424-00-125-0647 Excludes induction heating.
Alternate Parts: HCRE1075, 342421618131, 3424-2161-8131, 3424-00-125-0647, 00-125-0647, 3424001250647, 001250647
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
34 | NOV 20, 1968 | 00-125-0647 | 06243 ( FURNACE, HEAT TREATING, ELECTRIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 3424-00-125-0647
Part Number | Cage Code | Manufacturer |
---|---|---|
HCRE1075 | 00836 | AJAX ELECTRIC COMPANY |
3424-2161-8131 | 99998 | DEFENSE SUPPLY CENTER RICHMONDINDUSTRIAL PLANT EQUIPMENT /DLA/ |
Technical Data | NSN 3424-00-125-0647
Characteristic | Specifications |
---|---|
DESIGN TYPE | ELECTRODE SALT BATH |
MOUNTING TYPE | FLOOR |
WATTAGE RATING IN KILOWATTS | 45.0 |
MAXIMUM OPERATING TEMP | 185.0 DEG FAHRENHEIT |
OPERATING TEMP RANGE | +1350.0 TO +1850.0 DEG FAHRENHEIT |
TEMP CONTROL DEVICE TYPE | AUTOMATIC |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | 220.0 |
FREQUENCY RATING | 60.0 HERTZ NOMINAL |
PHASE | THREE |
INSIDE DEPTH | 30.000 INCHES NOMINAL |
INSIDE LENGTH | 12.000 INCHES NOMINAL |
INSIDE WIDTH | 12.000 INCHES NOMINAL |
TILTING HEARTH | NOT INCLUDED |
WORK HOLDING BASKET | NOT INCLUDED |
DOOR/OPENING LOCATION AND QUANTITY | 1 OPENING IN TOP |
ACCESS OPERATION METHOD | CQ ANY ACCEPTABLE |
COUNTERWEIGHT | NOT INCLUDED |
EQUIPMENT FOR FLAME CURTAIN | NOT INCLUDED |