Part Details | ELECTRIC HEAT TREATING FURNACE
3424-00-497-4223 Excludes induction heating.
Alternate Parts: D4470, 342421610943, 3424-2161-0943, 3424-00-497-4223, 00-497-4223, 3424004974223, 004974223
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
34 | OCT 07, 1970 | 00-497-4223 | 06243 ( FURNACE, HEAT TREATING, ELECTRIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 3424-00-497-4223
Part Number | Cage Code | Manufacturer |
---|---|---|
D4470 | 00836 | AJAX ELECTRIC COMPANY |
3424-2161-0943 | 99998 | DEFENSE SUPPLY CENTER RICHMONDINDUSTRIAL PLANT EQUIPMENT /DLA/ |
Technical Data | NSN 3424-00-497-4223
Characteristic | Specifications |
---|---|
DESIGN TYPE | ELECTRODE SALT BATH |
MOUNTING TYPE | FLOOR |
WATTAGE RATING IN KILOWATTS | 120.0 |
MAXIMUM OPERATING TEMP | 1050.0 DEG FAHRENHEIT |
OPERATING TEMP RANGE | +70.0 TO +1050.0 DEG FAHRENHEIT |
TEMP CONTROL DEVICE TYPE | AUTOMATIC |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | 480.0 |
FREQUENCY RATING | 60.0 HERTZ NOMINAL |
PHASE | THREE |
INSIDE DEPTH | 48.000 INCHES NOMINAL |
INSIDE LENGTH | 144.000 INCHES NOMINAL |
INSIDE WIDTH | 30.000 INCHES NOMINAL |
TILTING HEARTH | NOT INCLUDED |
WORK HOLDING BASKET | NOT INCLUDED |
DOOR/OPENING LOCATION AND QUANTITY | COVER ON TOP 1 |
ACCESS OPERATION METHOD | CS ANY ACCEPTABLE |
COUNTERWEIGHT | NOT INCLUDED |
EQUIPMENT FOR FLAME CURTAIN | NOT INCLUDED |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY MAXIMUM OPERATING TEMPERATURE,OPERATING TEMP RANGE |