NSN 4130-01-500-5902

Part Details | AIR COOLER UNIT

4130-01-500-5902 A unit comprising a fin and tube heat transfer element, filters and may or may not have a motor driven fan, inclosed in a casing for the purpose of cooling and removing moisture from the air in a space where the unit is installed. It may include electric heater and/or electrostatic precipitator. Excludes units containing compressor, condenser and means for introducing air from outside sources.

Alternate Parts: 111600D, 1116-00-D, FCUV56.0KWLVR, FCU-V5-6.0KW-LVR, FCUV56.0KWLV P, FCU-V5-6.0KW-LV P, 4130-01-500-5902, 01-500-5902, 4130015005902, 015005902

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41SEP 03, 200201-500-590211361 ( COOLER UNIT, AIR )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4130-01-500-5902
Part Number Cage Code Manufacturer
1116-00-D38450ENGINEERED COIL COMPANYDBA DRS MARLO COIL
FCU-V5-6.0KW-LVR38450ENGINEERED COIL COMPANYDBA DRS MARLO COIL
FCU-V5-6.0KW-LV PD9182ZF INDUSTRIEANTRIEBE WITTEN GMBH
Technical Data | NSN 4130-01-500-5902
Characteristic Specifications
OVERALL WIDTH39.000 INCHES NOMINAL
OVERALL HEIGHT52.000 INCHES NOMINAL
OVERALL DEPTH17.000 INCHES NOMINAL
CASE MATERIAL STEEL, GALVANIZED
CASE WITH BUILT-IN CONDENSATE DRAIN PAN INCLUDED
NOMINAL CAPACITY IN BTU PER HOUR30500.0 COOLING AND 30500.0 HEATING
HEATER WATTAGE RATING IN KILOWATTS6.0
TUBE MATERIAL COPPER
COIL TUBE QUANTITY1
TUBE CIRCUIT QUANTITY32
COOLING MEDIUM CHILLED WATER
SUPPLY CONNECTION SIZE0.625 IN O.D.
RETURN CONNECTION SIZE0.625 IN O.D.
FAN TYPEF ANY ACCEPTABLE
FAN DRIVE TYPE DIRECT
PRIME MOVER HORSEPOWER RATING0.500
OPERATING SPEED AT RATED CAPACITY IN RPM1800.0
SPECIAL FEATURESMIL-A-24775; REVERSABLE CONNECTIONS (LH/RH), HIGH IMPACT SHOCK AND VIBRATION RESISTANCE; HAS LVR (LOW VOLTAGE RELEASE) CAPABILITY
END ITEM IDENTIFICATIONFAN COIL UNIT