Part Details | AIR COOLER UNIT
4130-01-504-3985 A unit comprising a fin and tube heat transfer element, filters and may or may not have a motor driven fan, inclosed in a casing for the purpose of cooling and removing moisture from the air in a space where the unit is installed. It may include electric heater and/or electrostatic precipitator. Excludes units containing compressor, condenser and means for introducing air from outside sources.
Alternate Parts: M163855, M16385-5, 4130-01-504-3985, 01-504-3985, 4130015043985, 015043985
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | JAN 28, 2003 | 01-504-3985 | 11361 ( COOLER UNIT, AIR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4130-01-504-3985
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| M16385-5 | 36232 | LINCOLN ELECTRIC HOLDINGS INC. |
Technical Data | NSN 4130-01-504-3985
| Characteristic | Specifications |
|---|---|
| OVERALL WIDTH | 6.440 INCHES MINIMUM AND 6.560 INCHES MAXIMUM |
| OVERALL HEIGHT | 7.440 INCHES MINIMUM AND 7.560 INCHES MAXIMUM |
| OVERALL DEPTH | 1.940 INCHES MINIMUM AND 2.060 INCHES MAXIMUM |
| CASE MATERIAL | ANY ACCEPTABLE |
| CASE WITH BUILT-IN CONDENSATE DRAIN PAN | NOT INCLUDED |
| TUBE MATERIAL | ANY ACCEPTABLE |
| COIL TUBE QUANTITY | 7 |
| TUBE CIRCUIT QUANTITY | 1 |
| COOLING MEDIUM | AIR |
| CONNECTION TYPE | PIPE |
| SUPPLY CONNECTION SIZE | 0.380 INCH OUTER DIAMETER |
| RETURN CONNECTION SIZE | 0.380 INCH OUTER DIAMETER |
| SPECIAL FEATURES | MUST BE ABLE TO WITHDTAND 60 PSI STATIC PRESSURE TEST WITH OUT LEAKING; COMPLETE SOLDERED ASSY MUST NOT HAVE ANY BLOCKAGE WHICH WILL RESTRICT AIRFLOW THROUGH THE FINS OR SUPPLY AND RETURN PIPES |