Part Details | VANEAXIAL FAN
4140-00-433-6034 A nonpositive displacement mechanical device with guide vanes and having an axial fan impeller(s) inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes and pressures.
Alternate Parts: 8Y0067, 4140-00-433-6034, 00-433-6034, 4140004336034, 004336034
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | FEB 12, 1972 | 00-433-6034 | 04245 ( FAN, VANEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-00-433-6034
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 8Y0067 | 72957 | ELLIOTT COMPANYDIV JEANNETTE |
Technical Data | NSN 4140-00-433-6034
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | FIXED |
| DIAMETER | 21.345 INCHES MINIMUM AND 21.350 INCHES MAXIMUM |
| LENGTH | 68.375 INCHES NOMINAL |
| HOUSING INSIDE DIAMETER | 30.000 INCHES NOMINAL |
| QUANTITY | 1 |
| DRIVE TYPE | DIRECT |
| ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| PRIME MOVER TYPE | STEAM TURBINE |
| INCLOSURE TYPE | FULLY INCLOSED |
| PRIME MOVER POWER RATING | 193.700 HORSEPOWER |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 7480.0 |
| AIR FLOW RATE | 21500.0 CUBIC FEET PER MINUTE NOMINAL |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 40.0 INCHES OF WATER |
| STAGE QUANTITY | 1 |
| MOUNTING FACILITY TYPE AND QUANTITY | 12 UNTHREADED HOLE |
| REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY RIGHT HAND AIR DISCHARGE CONFIGURATIONAND SHALL BE FURNISHED WITHOUT THE FOLLOWING ITEMS,TWO /2/ EACH REMOTELY MOUNTED TACHOMETERS,FISHER FILTER REGULATOR,HAGEN RELAY SENDER,TWO /2/ BAILEY THREE-WAY TRANSFER VALVES,HAGENAIR LOCK VALVE |