NSN 4140-00-606-5429

Part Details | VANEAXIAL FAN

4140-00-606-5429 A nonpositive displacement mechanical device with guide vanes and having an axial fan impeller(s) inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes and pressures.

Alternate Parts: A30A4W6FF16305, 9W71128A30A4W6, 5007069250, 500706-9250, FF16932 FF17441, FF-16932 FF-17441, A30A4W6, MILF18953, MIL-F-18953, 9W71128A30A4W6, 9W71128A30A4W5, R13574CD3586, R1-3574-CD-3586, R13574A30A4W6, R1-3574-A30A4W6, 4140-00-606-5429, 00-606-5429, 4140006065429, 006065429

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41JAN 25, 197500-606-542904245 ( FAN, VANEAXIAL )
REFERENCE DRAWINGS & PICTURES

FIXED

Cross Reference | NSN 4140-00-606-5429
Part Number Cage Code Manufacturer
A30A4W6FF1630575477HOWDEN NORTH AMERICA INC.DBA HOWDEN NORTH AMERICA
9W71128A30A4W675477HOWDEN NORTH AMERICA INC.DBA HOWDEN NORTH AMERICA
500706-925075477HOWDEN NORTH AMERICA INC.DBA HOWDEN NORTH AMERICA
FF-16932 FF-1744175477HOWDEN NORTH AMERICA INC.DBA HOWDEN NORTH AMERICA
A30A4W681349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-F-1895381349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
9W71128A30A4W609519NEW PHILADELPHIA FAN COBUFFALO FORGE MARINE FANS
9W71128A30A4W5D9182ZF INDUSTRIEANTRIEBE WITTEN GMBH
R1-3574-CD-3586D9182ZF INDUSTRIEANTRIEBE WITTEN GMBH
R1-3574-A30A4W6D9182ZF INDUSTRIEANTRIEBE WITTEN GMBH
Technical Data | NSN 4140-00-606-5429
Characteristic Specifications
STYLE DESIGNATOR FIXED
LENGTH52.000 INCHES NOMINAL
HOUSING INSIDE DIAMETER44.188 INCHES MINIMUM AND 44.312 INCHES MAXIMUM
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED COUNTERCLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER65.0 DEG CELSIUS
ELECTRICAL CONNECTION TYPE WIRE LEAD
VOLTAGE IN VOLTS AND CURRENT TYPE440.0 AC
PHASE THREE
FREQUENCY IN HERTZ60.0
AIR FLOW RATE22400.0 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE4.2 INCHES OF WATER
FLOW DIRECTION INWARD