Part Details | VANEAXIAL FAN
4140-00-788-5969 A nonpositive displacement mechanical device with guide vanes and having an axial fan impeller(s) inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes and pressures.
Alternate Parts: 88121, 8812-1, 3A91104101, 3A91104-101, 88121, 8812-1, 4140-00-788-5969, 00-788-5969, 4140007885969, 007885969
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
41 | JAN 01, 1960 | 00-788-5969 | 04245 ( FAN, VANEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-00-788-5969
Part Number | Cage Code | Manufacturer |
---|---|---|
8812-1 | 99167 | HAMILTON SUNDSTRAND CORPORATION |
3A91104-101 | 98897 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN AERONAUTICS |
8812-1 | 55820 | UNITED TECHNOLOGIES CORPORATIONDBA PRATT & WHITNEY |
Technical Data | NSN 4140-00-788-5969
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | FIXED |
LENGTH | 7.470 INCHES NOMINAL |
HOUSING INSIDE DIAMETER | 6.500 INCHES NOMINAL |
DRIVE TYPE | DIRECT |
ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
INCLOSURE TYPE | FULLY INCLOSED |
PRIME MOVER POWER RATING | 2.750 HORSEPOWER |
VOLTAGE IN VOLTS AND CURRENT TYPE | 200.0 AC |
PHASE | THREE |
FREQUENCY IN HERTZ | 400.0 |
FLOW DIRECTION | OUTWARD |
STAGE QUANTITY | 2 |
FSC APPLICATION DATA | ELECTRONIC COOLING SYSTEM,ACFT |