Part Details | TUBEAXIAL FAN
4140-01-235-7980 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.
Alternate Parts: 0008005211, 000-8005-211, 4344011, 434401-1, 1N498000001, 034429, 034148, SPTSM,115AC,S,682YF, 4140-01-235-7980, 01-235-7980, 4140012357980, 012357980
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | JUL 06, 1986 | 01-235-7980 | 04244 ( FAN, TUBEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-01-235-7980
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 000-8005-211 | 94756 | BOEING COMPANY, THEDBA BOEING |
| 434401-1 | 00752 | EDO LLCDIV ANTENNA PRODUCTS |
| 1N498000001 | A2309 | LEONARDO SPA DIVISIONE SISTEMI DIDIFESA |
| 034429 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| 034148 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| SPTSM,115AC,S,682YF | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-01-235-7980
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | FIXED |
| LENGTH | 1.500 INCHES NOMINAL |
| HOUSING INSIDE DIAMETER | 4.125 INCHES NOMINAL |
| DRIVE TYPE | DIRECT |
| ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| SPEED ADJUSTMENTS | SINGLE SPEED |
| PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| INCLOSURE TYPE | FULLY INCLOSED |
| AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
| ELECTRICAL CONNECTION TYPE | CONNECTOR |
| PRIME MOVER POWER RATING | 14.0 WATTS |
| OPERATING SPEED AT RATED CAPACITY IN RPM | B2750.0$$B3250.0 |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
| PHASE | SINGLE |
| FREQUENCY IN HERTZ | B50.0$$B60.0 |
| AIR FLOW RATE | 930.0 CUBIC FEET PER MINUTE NOMINAL AND 110.0 CUBIC FEET PER MINUTE NOMINAL |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
| FLOW DIRECTION | OUTWARD |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 FLANGE AND 8 UNTHREADED HOLE |
| SPECIAL FEATURES | FAN PERFORMANCE SENSOR; SQ FLANGE EA END OF VENTURI |