Part Details | VANEAXIAL FAN
4140-01-300-8058 A nonpositive displacement mechanical device with guide vanes and having an axial fan impeller(s) inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes and pressures.
Alternate Parts: 9W57487, 9W-57487, XA2A4W6, MILF18953, MIL-F-18953, 9W57487, 9W-57487, 9W57487 REV M CD3603, 9W-57487 REV M- CD-3603, 79M10233A20, 79M-10233-A20, 69L4994, 4140-01-300-8058, 01-300-8058, 4140013008058, 013008058
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | MAY 18, 1989 | 01-300-8058 | 04245 ( FAN, VANEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-01-300-8058
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 9W-57487 | 75477 | HOWDEN NORTH AMERICA INC.DBA HOWDEN NORTH AMERICA |
| XA2A4W6 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-F-18953 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| 9W-57487 | 09519 | NEW PHILADELPHIA FAN COBUFFALO FORGE MARINE FANS |
| 9W-57487 REV M- CD-3603 | D9182 | ZF INDUSTRIEANTRIEBE WITTEN GMBH |
| 79M-10233-A20 | D9182 | ZF INDUSTRIEANTRIEBE WITTEN GMBH |
| 69L4994 | D9182 | ZF INDUSTRIEANTRIEBE WITTEN GMBH |
Technical Data | NSN 4140-01-300-8058
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | FIXED |
| LENGTH | 26.000 INCHES NOMINAL |
| HOUSING INSIDE DIAMETER | 15.500 INCHES NOMINAL |
| DRIVE TYPE | DIRECT |
| ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| SPEED ADJUSTMENTS | SINGLE SPEED |
| PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| INCLOSURE TYPE | FULLY INCLOSED |
| AMBIENT TEMP AT FULL RATED POWER | 65.0 DEG CELSIUS |
| ELECTRICAL CONNECTION TYPE | TERMINAL |
| PRIME MOVER POWER RATING | 1.500 HORSEPOWER |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 3450.0 |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 440.0 AC |
| PHASE | THREE |
| FREQUENCY IN HERTZ | 60.0 |
| AIR FLOW RATE | 2000.0 CUBIC FEET PER MINUTE NOMINAL |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
| FLOW DIRECTION | OUTWARD |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 FLANGE AND 36 UNTHREADED HOLE |
| ENVIRONMENTAL PROTECTION | DRIPPROOF AND EXPLOSION PROOF AND WATERPROOF |
| NONDEFINITIVE SPEC/STD DATA | X-A TYPE |