Part Details | TUBEAXIAL FAN
4140-01-305-9097 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.
Alternate Parts: 729001, 7290-01, ES729001, ES7290-01, 729001, 7290-01, ES729001, ES7290-01, 035598, 021639, 4140-01-305-9097, 01-305-9097, 4140013059097, 013059097
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | AUG 12, 1989 | 01-305-9097 | 04244 ( FAN, TUBEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-01-305-9097
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 7290-01 | 98255 | DRS SUSTAINMENT SYSTEMS, INC. |
| ES7290-01 | 98255 | DRS SUSTAINMENT SYSTEMS, INC. |
| 7290-01 | 20418 | DRS SUSTAINMENT SYSTEMS, INC.Use CAGE Code 98255 for cataloging |
| ES7290-01 | 20418 | DRS SUSTAINMENT SYSTEMS, INC.Use CAGE Code 98255 for cataloging |
| 035598 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| 021639 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-01-305-9097
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | FIXED |
| LENGTH | 1.670 INCHES MINIMUM AND 1.790 INCHES MAXIMUM |
| HOUSING INSIDE DIAMETER | 3.560 INCHES MINIMUM |
| DRIVE TYPE | DIRECT |
| ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| SPEED ADJUSTMENTS | SINGLE SPEED |
| PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| INCLOSURE TYPE | FULLY INCLOSED |
| AMBIENT TEMP AT FULL RATED POWER | -40.0 DEG CELSIUS AND 125.0 DEG CELSIUS |
| ELECTRICAL CONNECTION TYPE | CONNECTOR |
| PRIME MOVER POWER RATING | 45.0 WATTS |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 5950.0 |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
| PHASE | SINGLE |
| FREQUENCY IN HERTZ | 400.0 |
| AIR FLOW RATE | 100.0 CUBIC FEET PER MINUTE NOMINAL |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
| FLOW DIRECTION | INWARD |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 RIM |