Part Details | CIRCULATING FAN
4140-01-588-1672 A nonpositive displacement mechanical device having an axial fan impeller with or without a protective enclosure. It is designed to circulate air under free-airflow conditions, and may be equipped with a baffle(s) to deflect the air radially. It may be suspended from the ceiling, attached to the wall, or stand on a horizontal surface.
Alternate Parts: UF15KC12BTHR, UF15KC12-BTHR, 214902 ITEM13, 2149-02 ITEM-13, 4140-01-588-1672, 01-588-1672, 4140015881672, 015881672
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | SEP 03, 2010 | 01-588-1672 | 30260 ( FAN, CIRCULATING ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4140-01-588-1672
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| UF15KC12-BTHR | 0S2W9 | MECHATRONICS, INC.DBA NATIONAL PRECISION BEARING |
| 2149-02 ITEM-13 | 57487 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-01-588-1672
| Characteristic | Specifications |
|---|---|
| DRIVE TYPE | DIRECT |
| ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| INCLOSURE TYPE | FULLY INCLOSED |
| ELECTRICAL CONNECTION TYPE | TERMINAL |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
| PHASE | SINGLE |
| FREQUENCY IN HERTZ | 60.0 |
| FLOW DIRECTION | INWARD |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 RACK |
| END ITEM IDENTIFICATION | HEAT EXCHANGER |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | HEAT EXCHANGER/FAN ASSEMBLY NSSN RADIO ROOM |