Part Details | OXYGEN PRESSURE BOOSTER
4240-01-455-0183 An auxillary system specifically designed to mate with a diver's oxygen supply system. This device will increase the oxygen pressure to a greater than normal pressure, thus increasing the diver's depth range.
Alternate Parts: AGT3262, AGT-32/62, AGT3262, AGT-32/62, 4240-01-455-0183, 01-455-0183, 4240014550183, 014550183
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
42 | APR 20, 1998 | 01-455-0183 | 39069 ( BOOSTER, PRESSURE, OXYGEN ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4240-01-455-0183
Part Number | Cage Code | Manufacturer |
---|---|---|
AGT-32/62 | K6039 | HASKEL EUROPE LTD |
AGT-32/62 | 81400 | HASKEL INTERNATIONAL, INC.DBA BUTECH PRESSURE SYSTEMS |
Technical Data | NSN 4240-01-455-0183
Characteristic | Specifications |
---|---|
SPECIAL FEATURES | RATIO AIR DRIVE PISTON AREA 32; GAS PISTON AREA 62; OP TEMP 25 TO 150 DEG F; 2 STAGE GAS BOOSTER COMPRESSION; SINGLE AIR HEAD; 30 TO 2500 PSIG MAX RATED GAS SUPPLY; STATIC OUTLET 60 PA-2 PS; PISTON DISPLACEMENT 6.2 CU IN PER CYCLE; INLET/OUTLET 3/16 IN SAE OR 1/4 IN SUPERPRESSURE GAS PORT; A GAS SOURCE OF 1000 PSIG IS BOOSTED TO 5750 PSIG OUTLET USING 90 PSIG DRIVE OUTPUT; GAS FLOW WILL BE ABOUT 9 SC F/M; DRIVE CONSUMPTION 50 SCFM AT 90 PSIG; ITEM INCREASES OR BOOSTS GAS PRESSURE IN AIRCRAFT SERVICING OXYGEN TANKS TO PERMIT LONGER USAGE, FILLS ONBOARD EMERGENCY CYLINDERS, ALSO USED BY EMS PERSONNEL AND MAJOR DIVING CONTRACTORS |