Part Details | OXYGEN PRESSURE BOOSTER
4240-01-455-0184 An auxillary system specifically designed to mate with a diver's oxygen supply system. This device will increase the oxygen pressure to a greater than normal pressure, thus increasing the diver's depth range.
Alternate Parts: 27267AGT3262, 27267-AGT-32/62, 27267AGT3262, 27267-AGT-32/62, 4240-01-455-0184, 01-455-0184, 4240014550184, 014550184
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
42 | APR 20, 1998 | 01-455-0184 | 39069 ( BOOSTER, PRESSURE, OXYGEN ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4240-01-455-0184
Part Number | Cage Code | Manufacturer |
---|---|---|
27267-AGT-32/62 | K6039 | HASKEL EUROPE LTD |
27267-AGT-32/62 | 81400 | HASKEL INTERNATIONAL, INC.DBA BUTECH PRESSURE SYSTEMS |
Technical Data | NSN 4240-01-455-0184
Characteristic | Specifications |
---|---|
SPECIAL FEATURES | OP TEMP 25 TO 150 DEG F; RATIO AIR DRIVE PISTON AREA 32, GAS PISTON AREA 62; 2 STAGE GAS BOOSTER COMPRESSOR, SINGLE AIR HEAD; 30 TO 2500 PSIG MAX RATED GAS SUPPLY; 60 PA-2PS STATIC OUTLET; PISTON DISPLACEMENT 6.2 CU IN PER CYCLE; INLET/OUTLET 3/16 IN SAE OR 1/4 IN SUPERPRESSURE GAS PORT; A GAS SOURCE (PS) OF 1000 PSIG IS BOOSTED TO 5750 PSIG OUTLET USING 90 PSIG DRIVE (PA) OUTPUT, GAS FLOW WILL BE ABOUT 9 SC F/M; DRIVE CONSUMPTION 50 SCFM AT 90 PSIG; ITEM INCREASES OR BOOSTS GAS PRESSURE IN AIRCRAFT SERVICING OXYGEN TANKS TO PERMIT LONGER USAGE; FILLS ONBOARD EMERGENCY CYLINDERS, ALSO USED BY EMS PROVIDERS AND MAJOR DIVING CONTRACTORS; OPT 27267 SPECIALLY CLEANED TO BE HYDRO CARBON FREE |