Part Details | ROTARY VACUUM PUMP UNIT
4310-00-050-1392 An assembled unit consisting of a commonly mounted rotary vacuum pump(s), prime mover(s), and the necessary components to provide for a complete operation. It may include vacuum storage tank(s).
Alternate Parts: XX6100000, XX61-000-00, 4310-00-050-1392, 00-050-1392, 4310000501392, 000501392
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
43 | MAY 17, 1968 | 00-050-1392 | 29904 ( VACUUM PUMP UNIT, ROTARY ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4310-00-050-1392
Part Number | Cage Code | Manufacturer |
---|---|---|
XX61-000-00 | 08071 | EMD MILLIPORE CORPORATION |
Technical Data | NSN 4310-00-050-1392
Characteristic | Specifications |
---|---|
PUMP QUANTITY | 1 |
PRIME MOVER TYPE | ELECTRIC MOTOR |
PUMP BODY MATERIAL | IRON, CAST |
BODY SURFACE TREATMENT | ENAMEL |
VACUUM RATING | 254.0 TORR |
SYSTEM DESIGN | NONCORROSIVE |
SPECIFIC GAS FOR WHICH DESIGNED | AIR |
PUMPING ELEMENT TYPE | SLIDING VANE |
STAGE QUANTITY | 1 |
COOLING MEDIUM | AIR |
INTAKE CONNECTION QUANTITY | 1 |
INTAKE CONNECTION TYPE | N ANY ACCEPTABLE |
INTAKE CONNECTION OUTSIDE DIAMETER | 0.375 INCHES NOMINAL |
DISCHARGE CONNECTION QUANTITY | 1 |
DISCHARGE CONNECTION TYPE | N ANY ACCEPTABLE |
DISCHARGE CONNECTION OUTSIDE DIAMETER | 0.375 INCHES NOMINAL |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | 115.0 |
FREQUENCY IN HERTZ | 60.0 |
PHASE | SINGLE |
AIR DISPLACEMENT RATE | 0.2 CUBIC FEET PER MINUTE IN FREE AIR |
MOUNTING TYPE | B ANY ACCEPTABLE |
DRIVE CONNECTION TYPE | M ANY ACCEPTABLE |
SAFETY DEVICE TYPE | HIGH TEMPERATURE SHUTDOWN SWITCH |
FURNISHED ITEMS | ELECTRIC POWER CABLE AND EXHAUST FILTER AND EXHAUST MUFFLER AND INLET FILTER AND LUBRICATOR AND VACUUM GAGE AND PRESSURE GAGE |
OVERALL HEIGHT | 7.000 INCHES NOMINAL |
OVERALL LENGTH | 10.500 INCHES NOMINAL |
OVERALL WIDTH | 5.750 INCHES NOMINAL |