Part Details | CENTRIFUGAL PUMP UNIT
4320-00-287-4273 An assembled unit consisting of a commonly mounted centrifugal pump(s), prime mover(s), and the necessary components to provide for a complete operation.
Alternate Parts: H32W1INCH FLANGES, H-32W/1INCH FLANGES, E, 1022101 IN FLGS, 102210-1 IN FLGS, HV11NCHM0DEL, HV1-1NCHM0DEL, HVNF1IN.FLGS, HVNF1-IN.FLGS, 4320-00-287-4273, 00-287-4273, 4320002874273, 002874273
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 43 | JAN 01, 1963 | 00-287-4273 | 17988 ( PUMP UNIT, CENTRIFUGAL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4320-00-287-4273
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| H-32W/1INCH FLANGES | 52694 | ARMSTRONG PUMPS INC. |
| E | 06631 | ITT BELL AND GOSSET-HYDRONICSA UNIT OF ITT FLUID HANDLING DIV |
| 102210-1 IN FLGS | 06631 | ITT BELL AND GOSSET-HYDRONICSA UNIT OF ITT FLUID HANDLING DIV |
| HV1-1NCHM0DEL | 06631 | ITT BELL AND GOSSET-HYDRONICSA UNIT OF ITT FLUID HANDLING DIV |
| HVNF1-IN.FLGS | 06631 | ITT BELL AND GOSSET-HYDRONICSA UNIT OF ITT FLUID HANDLING DIV |
Technical Data | NSN 4320-00-287-4273
| Characteristic | Specifications |
|---|---|
| MAXIMUM DISCHARGE FLOW RATE | 30.0 GALLONS PER MINUTE |
| SUCTION LIFT | 7.500 FEET |
| OPERATING SPEED AT RATED CAPACITY | 1725.0 REVOLUTIONS PER MINUTE |
| PUMPING ELEMENT OPERATING POSITION | HORIZONTAL |
| CENTRIFUGAL PUMP DESIGN | RADIAL FLOW |
| CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
| CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
| STAGE QUANTITY | 1 |
| MEDIA FOR WHICH DESIGNED | WATER, FRESH |
| PUMP QUANTITY | 1 |
| INTAKE CONNECTION QUANTITY | 1 |
| INTAKE CONNECTION TYPE | ROUND FLANGE |
| DISCHARGE CONNECTION QUANTITY | 1 |
| DISCHARGE CONNECTION TYPE | ROUND FLANGE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| PRIME MOVER COOLING MEDIUM | AIR |
| PRIME MOVER QUANTITY | 1 |
| PRIME MOVER POWER RATING | 0.166 HORSEPOWER |
| CURRENT TYPE | AC |
| VOLTAGE IN VOLTS | 115.0 |
| FREQUENCY IN HERTZ | 60.0 |
| PHASE | SINGLE |
| INCLOSURE TYPE | OPEN |
| COOLING METHOD | AIR TO AIR COOLED |
| REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY GPM MAX RATED CAPACITY,SUCTION LIFT,INLET AND OUTLET CONNECTIONS |