NSN 4320-00-401-3737

Part Details | ROTARY PUMP UNIT

4320-00-401-3737 An assembled unit consisting of a commonly mounted rotary pump(s), prime mover(s), and the necessary components to provide for a complete operation.

Alternate Parts: FV664(MODEL FH695), FH696, FH695M, 4320-00-401-3737, 00-401-3737, 4320004013737, 004013737

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
43NOV 21, 196900-401-373718181 ( PUMP UNIT, ROTARY )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4320-00-401-3737
Part Number Cage Code Manufacturer
FV664(MODEL FH695)63097VIKING PUMP INC.
FH69663097VIKING PUMP INC.
FH695M63097VIKING PUMP INC.
Technical Data | NSN 4320-00-401-3737
Characteristic Specifications
MAXIMUM DISCHARGE FLOW RATE5.0 GALLONS PER MINUTE
DISCHARGE PRESSURE25.0 POUNDS PER SQUARE INCH GAGE
OPERATING SPEED AT RATED CAPACITY3450.0 REVOLUTIONS PER MINUTE
PUMPING ELEMENT OPERATING POSITION HORIZONTAL
ROTARY PUMP DESIGN GEAR
PUMP QUANTITY1
INTAKE CONNECTION QUANTITY1
INTAKE CONNECTION TYPE THREADED INTERNAL
INTAKE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR1.000-11-1 TO 2 NPT
DISCHARGE CONNECTION QUANTITY1
DISCHARGE CONNECTION TYPE THREADED INTERNAL
DISCHARGE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR0.750-14 NPT
PRIME MOVER TYPE ELECTRIC MOTOR
PRIME MOVER COOLING MEDIUM AIR
PRIME MOVER QUANTITY1
PRIME MOVER POWER RATING0.500 HORSEPOWER
CURRENT TYPE AC
VOLTAGE IN VOLTSB240.0$$B480.0
FREQUENCY IN HERTZ60.0
PHASE THREE
CURRENT RATING IN AMPSB1.6$$B0.8
INCLOSURE TYPE OPEN
ENVIRONMENTAL PROTECTION DRIPPROOF
COOLING METHOD SELF VENTILATED
MOUNTING TYPE BASE