NSN 4320-00-403-3254

Part Details | CENTRIFUGAL PUMP UNIT

4320-00-403-3254 An assembled unit consisting of a commonly mounted centrifugal pump(s), prime mover(s), and the necessary components to provide for a complete operation.

Alternate Parts: 1455471, 145547-1, 9420CA924, 4320-00-403-3254, 00-403-3254, 4320004033254, 004033254

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
43JUN 24, 197000-403-325417988 ( PUMP UNIT, CENTRIFUGAL )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4320-00-403-3254
Part Number Cage Code Manufacturer
145547-124930HARRIS CORPORATIONDBA ELECTRONIC SYSTEMS, RADAR
9420CA92495270SKURKA AEROSPACE INC.
Technical Data | NSN 4320-00-403-3254
Characteristic Specifications
MAXIMUM DISCHARGE FLOW RATE17.5 GALLONS PER MINUTE
TOTAL HEAD161.000 FEET
SUCTION LIFT22.000 FEET
OPERATING SPEED AT RATED CAPACITY1800.0 REVOLUTIONS PER MINUTE
PUMPING ELEMENT OPERATING POSITION HORIZONTAL
CENTRIFUGAL PUMP DESIGN RADIAL FLOW
CENTRIFUGAL PUMP IMPELLER QUANTITY1
CENTRIFUGAL PUMP IMPELLER SUCTION TYPE SINGLE
STAGE QUANTITY1
MEDIA FOR WHICH DESIGNED ETHYLENE GLYCOL AND WATER, FRESH
FEATURES PROVIDED SELF-PRIMING
PUMP QUANTITY1
INTAKE CONNECTION QUANTITY1
INTAKE CONNECTION TYPE THREADED INTERNAL
INTAKE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR1.125-11-1 TO 2 NPT
DISCHARGE CONNECTION QUANTITY1
DISCHARGE CONNECTION TYPE THREADED INTERNAL
DISCHARGE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR1.125-11-1 TO 2 NPT
PRIME MOVER TYPE ELECTRIC MOTOR
PRIME MOVER COOLING MEDIUM AIR
PRIME MOVER QUANTITY1
CURRENT TYPE AC
VOLTAGE IN VOLTS208.0
FREQUENCY IN HERTZ400.0
PHASE THREE
INCLOSURE TYPE PARTIALLY INCLOSED
ENVIRONMENTAL PROTECTION DRIPPROOF
COOLING METHOD AIR TO AIR COOLED
MOUNTING TYPE BASE