4330-01-043-1121 A filter having inlet and outlet connections and designed to be connected in a pipe, tube or hose line. For spin-on, base-mounted filtering devices with integral outer casings, see FILTER ELEMENT, FLUID. Excludes AIR CONDITIONER.
Alternate Parts: FHP16B15A1, FHP-16B15A1, HH9020A12UPSBP, 15P203BM150MM1, 15P-2-03B-M1-50-MM-1, 3322762, 332-2762, 3322762010, 332-2762-010, 4330-01-043-1121, 01-043-1121, 4330010431121, 010431121
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 43 | JUN 19, 1977 | 01-043-1121 | 32622 ( FILTER, FLUID ) |
REFERENCE DRAWINGS & PICTURES
DIVERTED FLOW BASKET STRAINER W/BOLTED COVER
Cross Reference | NSN 4330-01-043-1121
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| FHP-16B15A1 | 0E9N0 | DAVID BROWN HYDRAULICS INCDBA HYDRECO |
| HH9020A12UPSBP | 64130 | PALL INDUSTRIAL HYDRAULICS CORP |
| 15P-2-03B-M1-50-MM-1 | 05779 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC FILTER DIVISION |
| 332-2762 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
| 332-2762-010 | 95105 | ROCKWELL COLLINS, INC.DIV GOVERNMENT SYSTEMS - DALLAS |
Technical Data | NSN 4330-01-043-1121
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 4 DIVERTED FLOW BASKET STRAINER W/BOLTED COVER |
| BODY LENGTH | 4.900 INCHES NOMINAL |
| BODY OUTSIDE DIAMETER | 2.900 INCHES NOMINAL |
| BODY HEIGHT | 11.290 INCHES NOMINAL |
| DESIGN TYPE | REUSABLE |
| FILTRATION RATING IN MICRONS | 3.0 ABSOLUTE |
| MEDIA FOR WHICH DESIGNED | Y ANY ACCEPTABLE |
| MAXIMUM OPERATING PRESSURE | 3000.0 POUNDS PER SQUARE INCH |
| TEMP RATING | -45.0 DEG FAHRENHEIT MINIMUM AND 225.0 DEG FAHRENHEIT MAXIMUM |
| DROP PRESSURE | 38.5 POUNDS PER SQUARE INCH |
| DIFFERENTIAL PRESSURE | 50.0 POUNDS PER SQUARE INCH |
| FIRST INTAKE THREAD SERIES DESIGNATOR | UN |
| FIRST INTAKE NOMINAL THREAD SIZE | 1.062 INCHES |
| FIRST INTAKE THREAD QUANTITY PER INCH | 12 |
| FIRST INTAKE THREAD CLASS | 2B |
| FIRST INTAKE THREAD DIRECTION | RIGHT-HAND |
| FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | IDENTICAL TO FIRST INTAKE CONNECTION |
| MOUNTING HOLE QUANTITY | 2 |
| DISTANCE BETWEEN MOUNTING HOLE CENTERS | 3.120 INCHES NOMINAL |
| MOUNTING HOLE DIAMETER | 0.270 INCHES NOMINAL |
| FILTERING SYSTEM FOR WHICH DESIGNED | J$H |
| FEATURES PROVIDED | BY-PASS VALVE AND DIFFERENTIAL PRESSURE INDICATOR |
| SPECIAL FEATURES | POP-UP TYPE INDICATOR W/MANUAL RESET; PORTS PER SAE J514H |