Part Details | FLUID FILTER
4330-01-211-9498 A filter having inlet and outlet connections and designed to be connected in a pipe, tube or hose line. For spin-on, base-mounted filtering devices with integral outer casings, see FILTER ELEMENT, FLUID. Excludes AIR CONDITIONER.
Alternate Parts: 92A, 92812A, 92-812A, 92812A, 4330-01-211-9498, 01-211-9498, 4330012119498, 012119498
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 43 | JUL 03, 1985 | 01-211-9498 | 32622 ( FILTER, FLUID ) |
REFERENCE DRAWINGS & PICTURES
DIVERTED FLOW BASKET STRAINER W/BOLTED COVER
Cross Reference | NSN 4330-01-211-9498
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 92A | 51440 | PARKER-HANNIFIN CORPORATIONDBA FILTRATION & SEPARATION |
| 92-812A | 51440 | PARKER-HANNIFIN CORPORATIONDBA FILTRATION & SEPARATION |
| 92812A | 51440 | PARKER-HANNIFIN CORPORATIONDBA FILTRATION & SEPARATION |
Technical Data | NSN 4330-01-211-9498
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 0 DIVERTED FLOW BASKET STRAINER W/BOLTED COVER |
| BODY OUTSIDE DIAMETER | 2.625 INCHES NOMINAL |
| BODY HEIGHT | 5.125 INCHES NOMINAL |
| DESIGN TYPE | REUSABLE |
| FILTERING ELEMENT QUANTITY | 1 |
| FILTRATION RATING IN MICRONS | 0.1 NOMINAL |
| MEDIA FOR WHICH DESIGNED | AIR |
| MAXIMUM OPERATING PRESSURE | 250.0 POUNDS PER SQUARE INCH |
| TEMP RATING | 300.0 DEG FAHRENHEIT MAXIMUM |
| DROP PRESSURE | 2.0 POUNDS PER SQUARE INCH |
| FIRST INTAKE THREAD SERIES DESIGNATOR | NPT |
| FIRST INTAKE NOMINAL THREAD SIZE | 0.500 INCHES |
| FIRST INTAKE THREAD DIRECTION | RIGHT-HAND |
| FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | IDENTICAL TO FIRST INTAKE CONNECTION |
| MOUNTING HOLE QUANTITY | 2 |
| DISTANCE BETWEEN MOUNTING HOLE CENTERS | 1.378 INCHES NOMINAL |
| MOUNTING FACILITY THREAD SERIES DESIGNATOR | UNC |
| MOUNTING FACILITY NOMINAL THREAD SIZE | 0.190 INCHES |
| FEATURES PROVIDED | DRAIN COCK |