Part Details | FLUID FILTER ASSEMBLY
4330-01-259-0363 Two or more FILTER, FLUID on a common mounting or mounted on each other. They may be separable and operate in series, parallel, or individually.
Alternate Parts: 200DD25BEC25B3, 200-DD-25B-EC-25-B-3, 4330-01-259-0363, 01-259-0363, 4330012590363, 012590363
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 43 | JUL 11, 1987 | 01-259-0363 | 32623 ( FILTER ASSEMBLY, FLUID ) |
REFERENCE DRAWINGS & PICTURES
ROUND W/UNTHREADED BOLT HOLES
ROUND W/UNTHREADED BOLT HOLES
ROUND W/UNTHREADED BOLT HOLES
ROUND W/UNTHREADED BOLT HOLES
RAISED
RAISED
RAISED
RAISED
Cross Reference | NSN 4330-01-259-0363
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 200-DD-25B-EC-25-B-3 | 05779 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC FILTER DIVISION |
Technical Data | NSN 4330-01-259-0363
| Characteristic | Specifications |
|---|---|
| MESH SIZE | 400.0 |
| WIRE DIAMETER | 0.0018 INCHES NOMINAL |
| DESIGN TYPE | REUSABLE |
| UNIT QUANTITY | 2 |
| FILTERING ELEMENT QUANTITY | 2 |
| FILTRATION RATING IN MICRONS | 25.0 NOMINAL |
| MEDIA FOR WHICH DESIGNED | Y ANY ACCEPTABLE |
| MAXIMUM OPERATING PRESSURE | 750.0 POUNDS PER SQUARE INCH |
| TEMP RATING | -40.0 DEG FAHRENHEIT MINIMUM AND 225.0 DEG FAHRENHEIT MAXIMUM |
| FIRST INTAKE FLANGE SHAPE STYLE | ROUND W/UNTHREADED BOLT HOLES |
| FIRST INTAKE FLANGE OUTSIDE DIAMETER | 6.500 INCHES NOMINAL |
| FIRST INTAKE FLANGE THICKNESS | 1.312 INCHES NOMINAL |
| FIRST INTAKE FLANGE FACE STYLE | RAISED |
| FIRST INTAKE FLANGE RAISED FACE HEIGHT | 0.375 INCHES NOMINAL |
| FIRST INTAKE FLANGE RAISED FACE DIAMETER | 3.312 INCHES NOMINAL |
| FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | IDENTICAL TO FIRST INTAKE CONNECTION |
| MOUNTING HOLE QUANTITY | 12 |
| DISTANCE BETWEEN MOUNTING HOLE CENTERS | 1.250 INCHES NOMINAL AND 11.750 INCHES NOMINAL |
| MOUNTING FACILITY THREAD SERIES DESIGNATOR | UNC |
| MOUNTING FACILITY NOMINAL THREAD SIZE | 0.500 INCHES |
| FILTERING SYSTEM FOR WHICH DESIGNED | J$H |
| FEATURES PROVIDED | BY-PASS VALVE AND DRAIN PLUG AND MAGNET AND SWITCH-OVER VALVE |
| SPECIAL FEATURES | 25 PSI BYPASS; ELECTRICAL DIRT ALARM |