Part Details | FLUID FILTER
4330-01-273-5849 A filter having inlet and outlet connections and designed to be connected in a pipe, tube or hose line. For spin-on, base-mounted filtering devices with integral outer casings, see FILTER ELEMENT, FLUID. Excludes AIR CONDITIONER.
Alternate Parts: F315P240SAPS0MM, F315P240SAP50MM1, F3-15P-2-40SA-P-50-MM-1, 4330-01-273-5849, 01-273-5849, 4330012735849, 012735849
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 43 | FEB 26, 1988 | 01-273-5849 | 32622 ( FILTER, FLUID ) |
REFERENCE DRAWINGS & PICTURES
DIVERTED FLOW BASKET STRAINER W/BOLTED COVER
Cross Reference | NSN 4330-01-273-5849
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| F315P240SAPS0MM | 05779 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC FILTER DIVISION |
| F3-15P-2-40SA-P-50-MM-1 | 05779 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC FILTER DIVISION |
Technical Data | NSN 4330-01-273-5849
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 4 DIVERTED FLOW BASKET STRAINER W/BOLTED COVER |
| BODY OUTSIDE DIAMETER | 4.000 INCHES NOMINAL |
| BODY HEIGHT | 9.700 INCHES NOMINAL |
| DESIGN TYPE | REUSABLE |
| FILTERING ELEMENT QUANTITY | 1 |
| FILTRATION RATING IN MICRONS | 40.0 NOMINAL |
| MEDIA FOR WHICH DESIGNED | Y ANY ACCEPTABLE |
| MAXIMUM OPERATING PRESSURE | 2000.0 POUNDS PER SQUARE INCH |
| FIRST INTAKE THREAD SERIES DESIGNATOR | UN |
| FIRST INTAKE NOMINAL THREAD SIZE | 1.062 INCHES |
| FIRST INTAKE THREAD QUANTITY PER INCH | 12 |
| FIRST INTAKE THREAD CLASS | 3B |
| FIRST INTAKE THREAD DIRECTION | RIGHT-HAND |
| FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | IDENTICAL TO FIRST INTAKE CONNECTION |
| MOUNTING HOLE QUANTITY | 2 |
| DISTANCE BETWEEN MOUNTING HOLE CENTERS | 3.125 INCHES NOMINAL |
| MOUNTING HOLE DIAMETER | 0.266 INCHES NOMINAL |
| FILTERING SYSTEM FOR WHICH DESIGNED | FULL FLOW |