Part Details | FLUID FILTER
4330-01-342-4100 A filter having inlet and outlet connections and designed to be connected in a pipe, tube or hose line. For spin-on, base-mounted filtering devices with integral outer casings, see FILTER ELEMENT, FLUID. Excludes AIR CONDITIONER.
Alternate Parts: MFD160G10M12.05.1, MFD-160-G-10-M-1-2.0/5.1, 4330-01-342-4100, 01-342-4100, 4330013424100, 013424100
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 43 | JUL 22, 1991 | 01-342-4100 | 32622 ( FILTER, FLUID ) |
REFERENCE DRAWINGS & PICTURES
Y STRAINER W/THREADED COVER
Cross Reference | NSN 4330-01-342-4100
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| MFD-160-G-10-M-1-2.0/5.1 | 59793 | HYDAC CORP. |
Technical Data | NSN 4330-01-342-4100
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 2 Y STRAINER W/THREADED COVER |
| BODY LENGTH | 6.500 INCHES NOMINAL |
| BODY WIDTH | 5.300 INCHES NOMINAL |
| BODY HEIGHT | 10.080 INCHES NOMINAL |
| DISTANCE FROM BOTTOM OF BODY TO CENTER OF INLET | 8.500 INCHES NOMINAL |
| DESIGN TYPE | NONREUSABLE |
| FILTERING ELEMENT QUANTITY | 2 |
| FILTRATION RATING IN MICRONS | 10.0 NOMINAL |
| MEDIA FOR WHICH DESIGNED | Y ANY ACCEPTABLE |
| TEMP RATING | 15.0 DEG FAHRENHEIT MINIMUM AND 210.0 DEG FAHRENHEIT MAXIMUM |
| FIRST INTAKE THREAD SERIES DESIGNATOR | NPT |
| FIRST INTAKE NOMINAL THREAD SIZE | 1.500 INCHES |
| FIRST INTAKE THREAD DIRECTION | RIGHT-HAND |
| FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | IDENTICAL TO FIRST INTAKE CONNECTION |
| MOUNTING HOLE QUANTITY | 4 |
| MOUNTING FACILITY THREAD SERIES DESIGNATOR | UNC |
| MOUNTING FACILITY NOMINAL THREAD SIZE | 0.375 INCHES |
| FILTERING SYSTEM FOR WHICH DESIGNED | FULL FLOW |