Part Details | FLUID FILTER
4330-01-370-6112 A filter having inlet and outlet connections and designed to be connected in a pipe, tube or hose line. For spin-on, base-mounted filtering devices with integral outer casings, see FILTER ELEMENT, FLUID. Excludes AIR CONDITIONER.
Alternate Parts: H615B001 ITEM 64, B615B065, F351PNUAI14848, F3-51PNU-AI-14848, F351PNUAIEL35PP1, F3-51PNU-AI-EL-35-PP-1, F351PNUAE35PP1, F3-51PNU-A-E-35-PP-1, 4330-01-370-6112, 01-370-6112, 4330013706112, 013706112
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 43 | JAN 27, 1993 | 01-370-6112 | 32622 ( FILTER, FLUID ) |
REFERENCE DRAWINGS & PICTURES
DIVERTED FLOW BASKET STRAINER W/BOLTED COVER
Cross Reference | NSN 4330-01-370-6112
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| H615B001 ITEM 64 | 98523 | JERED LLCDBA PAR |
| B615B065 | 98523 | JERED LLCDBA PAR |
| F3-51PNU-AI-14848 | 05779 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC FILTER DIVISION |
| F3-51PNU-AI-EL-35-PP-1 | 05779 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC FILTER DIVISION |
| F3-51PNU-A-E-35-PP-1 | 05779 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC FILTER DIVISION |
Technical Data | NSN 4330-01-370-6112
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 0 DIVERTED FLOW BASKET STRAINER W/BOLTED COVER |
| BODY OUTSIDE DIAMETER | 6.120 INCHES NOMINAL |
| BODY HEIGHT | 15.240 INCHES NOMINAL |
| DESIGN TYPE | NONREUSABLE |
| FILTERING ELEMENT QUANTITY | 1 |
| MEDIA FOR WHICH DESIGNED | Y ANY ACCEPTABLE |
| MAXIMUM OPERATING PRESSURE | 3000.0 POUNDS PER SQUARE INCH |
| TEMP RATING | -40.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
| DIFFERENTIAL PRESSURE | 150.0 POUNDS PER SQUARE INCH |
| FIRST INTAKE THREAD SERIES DESIGNATOR | UN |
| FIRST INTAKE NOMINAL THREAD SIZE | 1.875 INCHES |
| FIRST INTAKE THREAD QUANTITY PER INCH | 12 |
| FIRST INTAKE THREAD CLASS | 2B |
| FIRST INTAKE THREAD DIRECTION | RIGHT-HAND |
| FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | IDENTICAL TO FIRST INTAKE CONNECTION |
| FILTERING SYSTEM FOR WHICH DESIGNED | BY-PASS FLOW |