Part Details | FLUID FILTER
4330-01-451-7404 A filter having inlet and outlet connections and designed to be connected in a pipe, tube or hose line. For spin-on, base-mounted filtering devices with integral outer casings, see FILTER ELEMENT, FLUID. Excludes AIR CONDITIONER.
Alternate Parts: 900MAMP30, 900MAM-P-30, 4330-01-451-7404, 01-451-7404, 4330014517404, 014517404
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 43 | DEC 30, 1997 | 01-451-7404 | 32622 ( FILTER, FLUID ) |
REFERENCE DRAWINGS & PICTURES
DIVERTED FLOW BASKET STRAINER W/BOLTED COVER
Cross Reference | NSN 4330-01-451-7404
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 900MAM-P-30 | 55752 | PARKER-HANNIFIN CORPORATIONDBA RACOR DIVISION |
Technical Data | NSN 4330-01-451-7404
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 0 DIVERTED FLOW BASKET STRAINER W/BOLTED COVER |
| BODY OUTSIDE DIAMETER | 6.000 INCHES NOMINAL |
| BODY HEIGHT | 17.000 INCHES NOMINAL |
| DESIGN TYPE | REUSABLE |
| FILTERING ELEMENT QUANTITY | 1 |
| FILTRATION RATING IN MICRONS | 30.0 NOMINAL |
| MAXIMUM OPERATING PRESSURE | 15.0 POUNDS PER SQUARE INCH |
| DROP PRESSURE | 0.34 POUNDS PER SQUARE INCH |
| FIRST INTAKE THREAD SERIES DESIGNATOR | UNF |
| FIRST INTAKE NOMINAL THREAD SIZE | 0.875 INCHES |
| FIRST INTAKE THREAD CLASS | 2B |
| FIRST INTAKE THREAD DIRECTION | RIGHT-HAND |
| FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | IDENTICAL TO FIRST INTAKE CONNECTION |
| BRACKET QUANTITY | 1 |
| MOUNTING HOLE QUANTITY | 2 |
| DISTANCE BETWEEN MOUNTING HOLE CENTERS | 4.500 INCHES NOMINAL |
| MOUNTING HOLE DIAMETER | 0.375 INCHES NOMINAL |
| FILTERING SYSTEM FOR WHICH DESIGNED | FULL FLOW |
| FEATURES PROVIDED | DRAIN PLUG |
| SPECIAL FEATURES | WATER SENSOR PROBE INCLUDED |