Part Details | FLUID FILTER
4330-01-516-1698 A filter having inlet and outlet connections and designed to be connected in a pipe, tube or hose line. For spin-on, base-mounted filtering devices with integral outer casings, see FILTER ELEMENT, FLUID. Excludes AIR CONDITIONER.
Alternate Parts: F351PNDBIML50PP1, 4330-01-516-1698, 01-516-1698, 4330015161698, 015161698
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 43 | DEC 22, 2003 | 01-516-1698 | 32622 ( FILTER, FLUID ) |
REFERENCE DRAWINGS & PICTURES
DIVERTED FLOW BASKET STRAINER W/BOLTED COVER
Cross Reference | NSN 4330-01-516-1698
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| F351PNDBIML50PP1 | 05779 | PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC FILTER DIVISION |
Technical Data | NSN 4330-01-516-1698
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 4 DIVERTED FLOW BASKET STRAINER W/BOLTED COVER |
| BODY LENGTH | 5.040 MILLIMETERS NOMINAL |
| BODY OUTSIDE DIAMETER | 3.630 MILLIMETERS NOMINAL |
| BODY WIDTH | 5.040 MILLIMETERS NOMINAL |
| BODY HEIGHT | 17.830 MILLIMETERS NOMINAL |
| DISTANCE FROM BOTTOM OF BODY TO CENTER OF INLET | 16.460A MILLIMETERS NOMINAL |
| DESIGN TYPE | NONREUSABLE |
| FILTERING ELEMENT QUANTITY | 1 |
| MAXIMUM OPERATING PRESSURE | 6000.0 POUNDS PER SQUARE INCH |
| TEMP RATING | -40.0 DEG FAHRENHEIT MINIMUM AND 225.0 DEG FAHRENHEIT MAXIMUM |
| DROP PRESSURE | 3000.0 POUNDS PER SQUARE INCH |
| SECOND INTAKE CONNECTION RELATIONSHIP TO FIRST INTAKE CONNECTION | IDENTICAL |
| FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | IDENTICAL TO FIRST INTAKE CONNECTION |
| FILTERING SYSTEM FOR WHICH DESIGNED | FULL FLOW |
| SPECIAL FEATURES | SEALS:FLUOROCARBON;HOUSING:BOWL DOWN;ELEMENT SIZE: ACCEPTS MIL-F-24402 SIZE B ELEMENT (INCLUDED);50PSID CALIBRATION ON BYPASS;PORTS DESCRIPTION: SAE-24 STRAIGHT THD BGSS 1 STD |
| END ITEM IDENTIFICATION | FILTER ASSEMBLY |