Part Details | SPACE HEATER
4520-00-379-3647 A device designed to burn various types of fuel within an inclosure which protects and confines the fire. It is used for the purpose of raising the temperature of the air in its immediate vicinity. The inclosure may be vented. Excludes HEATER, DUCT TYPE, PORTABLE and HEATER, SPACE, ELECTRIC.
Alternate Parts: T4000A, 4520-00-379-3647, 00-379-3647, 4520003793647, 003793647
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
45 | JAN 01, 1963 | 00-379-3647 | 03228 ( HEATER, SPACE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4520-00-379-3647
Part Number | Cage Code | Manufacturer |
---|---|---|
T4000A | 93084 | VBM CORP |
Technical Data | NSN 4520-00-379-3647
Characteristic | Specifications |
---|---|
HEAT DELIVERY RATE | 60000.0 BRITISH THERMAL UNIT |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | 120.0 |
FREQUENCY IN HERTZ | 60.0 |
PHASE | SINGLE |
HEATING ELEMENT TYPE | COMBUSTION CHAMBER |
HEAT MEDIUM TYPE | AIR |
FUEL TYPE | GASOLINE |
MOUNTING TYPE | FLOOR SURFACE, FREE STANDING, DUCTED |
HEIGHT | 28.000 INCHES NOMINAL |
WIDTH | 26.000 INCHES NOMINAL |
DEPTH | 12.000 INCHES NOMINAL |
AIR CIRCULATION DEVICE | SQUIRREL CAGE BLOWER |
QUANTITY | 2 |
PRIME MOVER TYPE | GASOLINE ENGINE |
CIRCULATED AIR TYPE | HEATED |
OPERATING CONTROL TYPE | THERMOSTATIC |
SPECIAL FEATURES | ONE CONTROL FLAME FAILURE TWO SWITCH,LIMIT |
FLUE CONNECTION LOCATION | ON RIGHT END IN CENTER,18 IN. FROM FLOOR |