4520-01-431-8927 A device designed to burn various types of fuel within an inclosure which protects and confines the fire. It is used for the purpose of raising the temperature of the air in its immediate vicinity. The inclosure may be vented. Excludes HEATER, DUCT TYPE, PORTABLE and HEATER, SPACE, ELECTRIC.
Alternate Parts: SHC35, MILPRF44493, MIL-PRF-44493, 4520-01-431-8927, 01-431-8927, 4520014318927, 014318927
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 45 | MAY 21, 1996 | 01-431-8927 | 03228 ( HEATER, SPACE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4520-01-431-8927
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| SHC35 | 81337 | ARMY, UNITED STATES DEPARTMENT OFTHE |
| MIL-PRF-44493 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 4520-01-431-8927
| Characteristic | Specifications |
|---|---|
| HEAT DELIVERY RATE | 35000.0 BRITISH THERMAL UNIT |
| CURRENT TYPE | DC |
| VOLTAGE IN VOLTS | B10.5$$B14.7 |
| CURRENT RATING IN AMPS | B20.0$$B15.0 |
| HEATING ELEMENT TYPE | BURNER |
| HEAT MEDIUM TYPE | AIR |
| FUEL FEED METHOD | EXTERNAL PUMP |
| INTEGRAL FUEL TANK CAPACITY | 5.0 GALLONS |
| FUEL TYPE | DF-2 REGULAR DIESEL FUEL OIL AND DF-A ARCTIC DIESEL FUEL OIL AND DF-1 WINTER DIESEL FUEL OIL AND JP-5 JET FUEL |
| IGNITION METHOD | GLOW PLUG |
| MOUNTING TYPE | FLOOR SURFACE, FREE STANDING, DUCTED |
| HEIGHT | 14.000 INCHES NOMINAL |
| WIDTH | 18.000 INCHES NOMINAL |
| DEPTH | 40.000 INCHES NOMINAL |
| MAXIMUM AIR FLOW RATE | 250.0 CUBIC FEET PER MINUTE |
| CIRCULATED AIR TYPE | HEATED |
| OPERATING CONTROL TYPE | HAND SWITCH |
| SPECIAL FEATURES | THE SPACE HEATER CONVECTIVE (SHC) IS A 35K BTU THERMOELECTRIC HEATER THAT PROVIDES FORCED HOT AIR CIRCULATION FOR SHELTERS WITHOUT THE NEED FOR AN EXTERNAL POWER SUPPLY. THIS ELIMINATES THE FOR A FIELD GENERATOR. THE SHC'S INTENDED APPLICATIONS INCLUDE THE MODULAR COMMAND POST SYSTEM, TOC'S AND OTHER TENT HOUSING EXPENXIVE ELECTRONICS EQUIPMENT. CONVERTS WASTE HEAT INTO ELECTRICAL ENERGY, WHICH IS USED TO POWER THE BLOWERS, PUMPS, IGNITION SYSTEM, SAFETY SYSTEM, AND CONTROL DEVICES, AND RECHARGES ITS OWN STARTING BATTERY. SEE ARMY OPERATOR'S MANUAL TM-10-4520-262-12 & P. |