NSN 4810-00-941-4113

Part Details | SOLENOID VALVE

4810-00-941-4113 A valve having two or more ports with valve stem or pilot needle in a normally open or closed position. It is specifically designed to stop or start or change the flow of fluid by means of the magnetic action of an electric coil on a moveable core or plunger. The valve may be equipped with a manual opening or closing device. For items with three or more ports that utilize a reciprocating slide with recess areas which mate with ports in an integral or replaceable ported sleeve, see VALVE (1), LINEAR, DIRECTIONAL CONTROL. It may be inline or cartridge (manifold) design. Excludes VALVE (1), BUTTERFLY.

Alternate Parts: 826220, 8262D20, HVA31835, HVA31-835, 04F20C1106AIFGC80, 04F20C1106AIFGC80, 64C42510, 4810-00-941-4113, 00-941-4113, 4810009414113, 009414113

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
48DEC 07, 196500-941-411310998 ( VALVE, SOLENOID )
REFERENCE DRAWINGS & PICTURES

STRAIGHT THRU

Cross Reference | NSN 4810-00-941-4113
Part Number Cage Code Manufacturer
82622004845AUTOMATIC SWITCH COMPANY
8262D2004845AUTOMATIC SWITCH COMPANY
HVA31-83504845AUTOMATIC SWITCH COMPANY
04F20C1106AIFGC8093781PARKER-HANNIFIN CORPORATIONDBA FLUID CONTROL DIVISION
04F20C1106AIFGC8081978PARKER-HANNIFIN CORPORATIONDBA FLUID CONTROLS DIVISION
64C4251098749SACRAMENTO AIR LOGISTICS CENTERSM-ALC/LIIL
Technical Data | NSN 4810-00-941-4113
Characteristic Specifications
STYLE DESIGNATOR STRAIGHT THRU
FLOW CONTROL DEVICE DISK
VALVE OPERATION METHOD SOLENOID
VOLTAGE IN VOLTS AND CURRENT TYPE24.0 DC
CURRENT RATING IN AMPS0.404
FLOW CONTROL DEVICE NORMAL OPERATION POSITION CLOSED
INLET/OUTLET OPERATING PRESSURE DIFFERENTIAL150.0 POUNDS PER SQUARE INCH NOMINAL
APERTURE DIAMETER0.094 INCHES NOMINAL
MOUNTING POSITIONR$DVT