NSN 5331-01-251-4738

Part Details | O-RING

5331-01-251-4738 A nonmetallic circular item with an aperature, having a solid round cross-section. They are used primarily for sealing. For items with other than round cross section, see PACKING,PREFORMED. For noncircular items with a round cross-section, see SEAL,NONMETALLIC ROUND SECTION and RUBBER,ROUND SECTION.

Alternate Parts: PO0319NRP, PO012514738, LLHX47693, LL-HX4-7693, LO1660, 82057869616, 820-5786961-6, 2141E54080, 2-141E540-80, 5331-01-251-4738, 01-251-4738, 5331012514738, 012514738

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
53MAR 19, 198701-251-473847946 ( O-RING )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5331-01-251-4738
Part Number Cage Code Manufacturer
PO0319NRP14153DEFENSE LOGISTICS AGENCYDBA DEFENSE SUPPLY CENTER
PO01251473814153DEFENSE LOGISTICS AGENCYDBA DEFENSE SUPPLY CENTER
LL-HX4-769314153DEFENSE LOGISTICS AGENCYDBA DEFENSE SUPPLY CENTER
LO166016236DLA LAND AND MARITIMEDBA ENGINEERING AND TECHNICAL
820-5786961-653711NAVAL SEA SYSTEMS COMMAND
2-141E540-8002697PARKER-HANNIFIN CORPORATIONDBA O'RING DIVISION OF PARKER
Technical Data | NSN 5331-01-251-4738
Characteristic Specifications
MATERIAL RUBBER ETHYLENE-PROPYLENE CLASS EPM
TEMP RATING-70.0 DEG FAHRENHEIT AND 400.0 DEG FAHRENHEIT
CENTER HOLE DIAMETER2.280 INCHES MINIMUM AND 2.320 INCHES MAXIMUM
CROSS-SECTIONAL HEIGHT0.100 INCHES MINIMUM AND 0.106 INCHES MAXIMUM
TEST DATA DOCUMENT81349-MIL-P-23199 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSAS DIFFERENTIATED BY MATERIAL WHICH MUST CONFORM TO SHIPS PARTS CONTROL CENTER SPECIAL QUALITY CONTROL PROVISIONS AND CERTIFIED FREE FROM MERCURY CONTAMINATION
CRITICALITY CODE JUSTIFICATIONZZZY