Part Details | RADAR TRANSMITTER
5840-01-475-2319 A component which generates electrical signals of proper frequency and form which when applied to an antenna will propagate electromagnetic waves into space, the reflected wave being utilized for radar applications. May include an integral modulator and accessories.
Alternate Parts: 638041, 63804-1, 2007789001, 2007789-001, 5840-01-475-2319, 01-475-2319, 5840014752319, 014752319
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 58 | MAY 25, 2000 | 01-475-2319 | 00501 ( TRANSMITTER, RADAR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5840-01-475-2319
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 63804-1 | 3Z966 | APPLIED SYSTEMS ENGINEERING, INC. |
| 2007789-001 | 66948 | HARRIS CORPORATIONDBA GOVERNMENT COMMUNICATIONS |
Technical Data | NSN 5840-01-475-2319
| Characteristic | Specifications |
|---|---|
| TRANSMITTED SIGNAL FREQUENCY RATING | 13.4 GIGAHERTZ MINIMUM AND 13.9 GIGAHERTZ MAXIMUM |
| TRANSMITTER BAND QUANTITY | 1 |
| TRANSMITTER CHANNEL QUANTITY | 1 |
| INTEGRAL MODULATOR | INCLUDED |
| PULSE DURATION | 0.4 MICROSECONDS |
| PULSE REPETITION RATE | 4.0 KILOHERTZ |
| POWER OUTPUT | 68.0 KILOWATTS MINIMUM |
| ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| SPECIAL FEATURES | E.S.D. CRITICAL UNIT |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| INSTALLATION DESIGN | FIXED |
| END ITEM IDENTIFICATION | AN/MST-T1A, "M" CONFIGURATION |
| SUPPLEMENTARY FEATURES | C/O MAGNATRON ASSEMBLY, POWER SUPPLIES, FILTERS, FERRITE MODULATOR, OUTPUT WAVEGUIDE SWITCH, FULL POWER DUMMY LOAD, AIR COOLING SYSTEM, AND CONTROL/MONITORING EQUIPMENT; UNIT CAN BE OPERATED REMOTELY VIA RS-485 DATA INTERFACE |
| FUNCTIONAL DESCRIPTION | KU BAND OPERATION |