Part Details | THERMAL RESISTOR
5905-00-521-0442 A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.
Alternate Parts: 51TF41P0RM5PCT, 7142852010, 714-2852-010, 5905-00-521-0442, 00-521-0442, 5905005210442, 005210442
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | AUG 19, 1974 | 00-521-0442 | 00309 ( RESISTOR, THERMAL ) |
REFERENCE DRAWINGS & PICTURES
SEALED OR COATED BEAD
Cross Reference | NSN 5905-00-521-0442
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 51TF41P0RM5PCT | 90634 | GULTON INDUSTRIES INC |
| 714-2852-010 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
Technical Data | NSN 5905-00-521-0442
| Characteristic | Specifications |
|---|---|
| ZERO POWER RESISTANCE | 100.000 KILOHMS |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | M5.0/P5.0 |
| AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
| MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
| THERMAL TIME CONSTANT IN SECONDS | 3.0 |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 1.4 |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | M4.96 |
| STYLE DESIGNATOR | 7 SEALED OR COATED BEAD |
| BODY LENGTH | 0.070 INCHES NOMINAL |
| BODY WIDTH | 0.075 INCHES MAXIMUM |
| BODY HEIGHT | 0.070 INCHES NOMINAL |
| INCLOSURE TYPE | ENCAPSULATED |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| TERMINAL LENGTH | 2.000 INCHES MINIMUM |
| TERMINAL DIAMETER | 0.010 INCHES NOMINAL |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TEST DATA DOCUMENT | 13499-714-2852 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |