NSN 5905-00-595-8621

Part Details | WIRE WOUND FIXED RESISTOR

5905-00-595-8621 A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self supporting. Opposition to the flow of current is an inherent property of the resistance wire and is manifest by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE.

Alternate Parts: LO1758, KFD310, N112E, KFD310, 5905-00-595-8621, 00-595-8621, 5905005958621, 005958621

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 10, 197500-595-862100010 ( RESISTOR, FIXED, WIRE WOUND )
REFERENCE DRAWINGS & PICTURES

RADIAL TERMINAL EACH END

Cross Reference | NSN 5905-00-595-8621
Part Number Cage Code Manufacturer
LO175816236DLA LAND AND MARITIMEDBA ENGINEERING AND TECHNICAL
KFD31006RP6DRS CONSOLIDATED CONTROLS, INC.
N112E02750EATON AEROSPACE LLCDIV FLUID & ELECTRICAL DISTRIBUTION
KFD31002750EATON AEROSPACE LLCDIV FLUID & ELECTRICAL DISTRIBUTION
Technical Data | NSN 5905-00-595-8621
Characteristic Specifications
ELECTRICAL RESISTANCE500.000 OHMS
RESISTANCE TOLERANCE IN PERCENTM1.000/P1.000
POWER DISSIPATION RATING IN WATTS0.500 FREE AIR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER125.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER145.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUSM20.0/P20.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUSM65.0/P145.0
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR RADIAL TERMINAL EACH END
BODY DIAMETER0.562 INCHES NOMINAL
BODY LENGTH1.000 INCHES NOMINAL
TERMINAL TYPE TAB, SOLDER LUG
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL LENGTH0.375 INCHES NOMINAL
TERMINAL WIDTH0.188 INCHES NOMINAL
SPECIAL FEATURESITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO1758
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSREFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP
CRITICALITY CODE JUSTIFICATIONZZZY