Part Details | THERMAL RESISTOR
5905-01-029-0870 A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.
Alternate Parts: 65A520PCT, 65A5-20PCT, 65A520PCT, 65A5-20PCT, S65A5PCT20, S65A5PCT20, 7143233170, 714-3233-170, 5905-01-029-0870, 01-029-0870, 5905010290870, 010290870
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | OCT 16, 1976 | 01-029-0870 | 00309 ( RESISTOR, THERMAL ) |
REFERENCE DRAWINGS & PICTURES
SEALED OR COATED BEAD
Cross Reference | NSN 5905-01-029-0870
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 65A5-20PCT | 58250 | BALLANTYNE OF OMAHA INC. |
| 65A5-20PCT | 83186 | MEAS US LLCDIV TEMPERATURE PRODUCTS GROUP |
| S65A5PCT20 | 83186 | MEAS US LLCDIV TEMPERATURE PRODUCTS GROUP |
| S65A5PCT20 | 1L9U5 | MEASUREMENT SPECIALTIES, INC. |
| 714-3233-170 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
Technical Data | NSN 5905-01-029-0870
| Characteristic | Specifications |
|---|---|
| ZERO POWER RESISTANCE | 5.000 MEGOHMS |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | M20.0/P20.0 |
| AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
| MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
| THERMAL TIME CONSTANT IN SECONDS | 8.0 |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 0.35 |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | M5.40 |
| STYLE DESIGNATOR | SEALED OR COATED BEAD |
| BODY OUTSIDE DIAMETER | 0.043 INCHES NOMINAL |
| INCLOSURE TYPE | ENCAPSULATED |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| TERMINAL LENGTH | 0.500 INCHES NOMINAL |
| TERMINAL DIAMETER | 0.004 INCHES NOMINAL |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TEST DATA DOCUMENT | 13499-714-3233-170 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |