Part Details | FILM FIXED RESISTOR NETWORK
5905-01-034-0795 An arrangement of multiple fixed resistive elements or discrete resistors permanently encased, encapsulated, or potted together, to form an inseparable unit. The resistive elements, consisting of a thin layer of conductive material deposited on or fused to an insulating base, usually are electrically connected to each other and may be arranged in any circuit configuration. Excludes RESISTOR, FIXED (as modified); RESISTOR ASSEMBLY; RESISTOR NETWORK, FIXED-VARIABLE; and RESISTOR SET, MATCHED.
Alternate Parts: 7000813, 34A1024, 5905-01-034-0795, 01-034-0795, 5905010340795, 010340795
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 18, 1977 | 01-034-0795 | 32068 ( RESISTOR NETWORK, FIXED, FILM ) |
REFERENCE DRAWINGS & PICTURES
LADDER NETWORK
TERMINALS ONE END
Cross Reference | NSN 5905-01-034-0795
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 7000813 | 93322 | GE AVIATION SYSTEMS LLCDBA GE AVIATION |
| 34A1024 | 01121 | ROCKWELL AUTOMATION, INC. |
Technical Data | NSN 5905-01-034-0795
| Characteristic | Specifications |
|---|---|
| POWER DISSIPATION RATING IN WATTS | 1.600 TOTAL NETWORK |
| AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
| AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 125.0 |
| TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | M100.0/P100.0 |
| TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | M65.0/P125.0 |
| SCHEMATIC DIAGRAM DESIGNATOR | LADDER NETWORK |
| INCLOSURE METHOD | HERMETICALLY SEALED |
| STYLE DESIGNATOR | 0 TERMINALS ONE END |
| BODY LENGTH | 0.745 INCHES MAXIMUM |
| BODY WIDTH | 0.245 INCHES NOMINAL |
| BODY HEIGHT | 0.100 INCHES NOMINAL |
| TERMINAL TYPE | TAB, SOLDER LUG |
| TERMINAL QUANTITY | 14 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL LENGTH | 0.174 INCHES NOMINAL |
| TEST DATA DOCUMENT | 93322-7000813 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |