NSN 5905-01-075-7328

Part Details | THERMAL RESISTOR

5905-01-075-7328 A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.

Alternate Parts: RTH42ES332J, MILT2364819, MIL-T-23648/19, GT838M332, TG18332J, TG1/8332J, 5905-01-075-7328, 01-075-7328, 5905010757328, 010757328

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59APR 26, 197901-075-732800309 ( RESISTOR, THERMAL )
REFERENCE DRAWINGS & PICTURES

BEAD

Cross Reference | NSN 5905-01-075-7328
Part Number Cage Code Manufacturer
RTH42ES332J81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-T-23648/1981349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
GT838M33226512NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MISSION SYSTEMS
TG1/8332J33809TEXAS INSTRUMENTS INC
Technical Data | NSN 5905-01-075-7328
Characteristic Specifications
ZERO POWER RESISTANCE3.300 KILOHMS
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMPM5.0/P5.0
MAXIMUM POWER DISSIPATION RATING0.25 WATTS
AMBIENT TEMP AT FULL RATED POWER25.0 DEG CELSIUS
MAXIMUM OPERATING TEMP125.0 DEG CELSIUS
THERMAL TIME CONSTANT IN SECONDS60.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS2.5
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS0.55
STYLE DESIGNATOR5 BEAD
BODY LENGTH0.285 INCHES NOMINAL
BODY OUTSIDE DIAMETER0.100 INCHES NOMINAL
INCLOSURE TYPE HERMETICALLY SEALED
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
TERMINAL LENGTH1.200 INCHES MINIMUM
TERMINAL DIAMETER0.020 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
TEST DATA DOCUMENT81349-MIL-T-23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
REFERENCE TEMP IN DEG CELSIUS25.0