Part Details | PAPER DIELECTRIC FIXED CAPACITOR
5910-00-051-9447 A capacitor whose capacitance value cannot be adjusted or varied, having paper as the dielectric material. It may be a single unit or consist of two or more fixed units which cannot be seperated. For items whose dielectric material consist of plasticized (plastic impregnated) paper or paper-plastic combinations, see CAPACITOR, FIXED, PLASTIC DIELECTRIC. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALIZED, PAPER-PLASTIC DIELECTRIC.
Alternate Parts: 118P10406S4, 51F104S20, 1080021360, 108-002-1360, RJK339261, RJK33926/1, 118P10406S4, 5910-00-051-9447, 00-051-9447, 5910000519447, 000519447
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1961 | 00-051-9447 | 00003 ( CAPACITOR, FIXED, PAPER DIELECTRIC ) |
REFERENCE DRAWINGS & PICTURES
W/O MTG FACILITIES, AXIAL TERMINALS
NO COMMON OR GROUNDED ELECTRODE(S)
Cross Reference | NSN 5910-00-051-9447
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 118P10406S4 | 01884 | EXXELIA DEARBORN, INC.DIV EXXELIA DEARABORN |
| 51F104S20 | 72928 | GULTON INDUSTRIES INC GUDEMAN DIV |
| 108-002-1360 | 95542 | NORTHROP GRUMMAN SYSTEMS CORPORATION |
| RJK33926/1 | S3092 | RHEINMETALL AIR DEFENCE AG |
| 118P10406S4 | 56289 | SPRAGUE ELECTRIC COWORLD HQS |
Technical Data | NSN 5910-00-051-9447
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 0.100 MICROFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -20.00 TO +20.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 600.0 DC SINGLE SECTION |
| NONDERATED OPERATING TEMP | 0.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
| BODY DIAMETER | 0.500 INCHES NOMINAL |
| BODY LENGTH | 1.125 INCHES NOMINAL |
| SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| CASE MATERIAL | METAL |
| CASE INSULATION MATERIAL | PLASTIC |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |