Part Details | BAND PASS FILTER
5915-00-321-0235 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).
Alternate Parts: 32107293120, 32-107293-120, 32107293120, 32-107293-120, 5915-00-321-0235, 00-321-0235, 5915003210235, 003210235
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | NOV 14, 1973 | 00-321-0235 | 00209 ( FILTER, BAND PASS ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
Cross Reference | NSN 5915-00-321-0235
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 32-107293-120 | 04655 | GENERAL DYNAMICS MISSION SYSTEMS,INC. |
| 32-107293-120 | 18796 | MURATA ERIE NORTH AMERICA INCSTATE COLLEGE OPNS |
Technical Data | NSN 5915-00-321-0235
| Characteristic | Specifications |
|---|---|
| REFERENCE FREQUENCY PER FUNCTION | ZZ120.0 KILOHERTZ |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 6.0 BLANK |
| FREQUENCY BAND WIDTH PER FUNCTION | ZZ119.25 KILOHERTZ AND ZZ120.75 KILOHERTZ |
| SOURCE IMPEDANCE RATING PER FUNCTION | ZZ1.0 KILOHMS |
| LOAD IMPEDANCE PER FUNCTION | ZZ1.0 KILOHMS |
| INCLOSURE TYPE | ENCASED |
| STYLE DESIGNATOR | 0 RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| BODY LENGTH | 1.500 INCHES NOMINAL |
| BODY HEIGHT | 2.800 INCHES MAXIMUM |
| BODY WIDTH | 1.000 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.125 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.625 INCHES NOMINAL |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
| NOMINAL THREAD SIZE | 0.112 INCHES |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | ZZ116.50 KILOHERTZ AND ZZ119.25 KILOHERTZ AND ZZ120.75 KILOHERTZ AND ZZ123.50 KILOHERTZ |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | ZZ60.0 MINIMUM AND ZZ3.0 MAXIMUM AND ZZ3.0 MAXIMUM AND ZZ60.0 MINIMUM |
| OPERATING TEMP RANGE | +0.0 TO +60.0 DEG CELSIUS |