NSN 5915-00-930-4185

Part Details | BAND PASS FILTER

5915-00-930-4185 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).

Alternate Parts: 049515, 0495-15, CC049515, CC0495-15, F30885, B9165015, B9-1650-15, CSC1932T, CSC19-32T, LDFL10130, FL10015, SMC56333515, SMC563335-15, 5915-00-930-4185, 00-930-4185, 5915009304185, 009304185

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59MAY 20, 196600-930-418500209 ( FILTER, BAND PASS )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE

Cross Reference | NSN 5915-00-930-4185
Part Number Cage Code Manufacturer
0495-1532840CONOLOG CORPORATIONDBA INIVEN
CC0495-1532840CONOLOG CORPORATIONDBA INIVEN
F3088572149ELECTRONIC TRANSFORMER CORP.DIV ELECTRONIC TRANSFORMER
B9-1650-1514304HARRIS CORPORATIONDBA HARRIS RF COMMUNICATION
CSC19-32T09376OMNITEC DATA CORPSUB OF NYTRONICS INC
LDFL1013010241TELEPHONE SYSTEMS/COMMUNICATIONS
FL1001510241TELEPHONE SYSTEMS/COMMUNICATIONS
SMC563335-1580063US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS
Technical Data | NSN 5915-00-930-4185
Characteristic Specifications
REFERENCE FREQUENCY PER FUNCTIONZZ2.805 KILOHERTZ
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS10.5 BLANK
FREQUENCY BAND WIDTH PER FUNCTIONZZ2.75 KILOHERTZ AND ZZ2.86 KILOHERTZ
INPUT IMPEDANCE PER FUNCTION W/LOADZZ600.0 OHMS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTZZ600.0 OHMS
INCLOSURE TYPE HERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITYQ1 STANDARD TUBE BASE
STYLE DESIGNATOR RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
OVERALL HEIGHT6.688 INCHES NOMINAL
BODY LENGTH1.500 INCHES NOMINAL
BODY HEIGHT6.188 INCHES NOMINAL
BODY WIDTH1.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY1 TERMINAL
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONZZ2.675 KILOHERTZ AND ZZ2.75 KILOHERTZ AND ZZ2.860 KILOHERTZ AND ZZ2.935 KILOHERTZ
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSZZ38.0 MINIMUM AND ZZ6.0 MAXIMUM AND ZZ6.0 MAXIMUM AND ZZ38.0 MINIMUM
OPERATING TEMP RANGE+0.0 TO +50.0 DEG CELSIUS
BODY MATERIAL METAL