NSN 5915-00-968-4870

Part Details | BAND PASS FILTER

5915-00-968-4870 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).

Alternate Parts: GS66834, GS66834, GS66834, 5915-00-968-4870, 00-968-4870, 5915009684870, 009684870

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196200-968-487000209 ( FILTER, BAND PASS )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE

Cross Reference | NSN 5915-00-968-4870
Part Number Cage Code Manufacturer
GS6683464959AMERICAN TELEPHONE AND TELEGRAPH CO
GS668343B4M0LUCENT TECHNOLOGIES INCCORPORATE HEADQUARTERS
GS6683406KW9LUCENT TECHNOLOGIES INCDBA FEDERAL MARKETING GROUP
Technical Data | NSN 5915-00-968-4870
Characteristic Specifications
REFERENCE FREQUENCY PER FUNCTIONZZ600.0 HERTZ
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.7 BLANK
FREQUENCY BAND WIDTH PER FUNCTIONZZ200.00 HERTZ AND ZZ1.00 KILOHERTZ
INPUT IMPEDANCE PER FUNCTION W/LOADZZ600.0 OHMS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTZZ600.0 OHMS
INCLOSURE TYPE HERMETICALLY SEALED
STYLE DESIGNATOR RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
OVERALL HEIGHT4.262 INCHES NOMINAL
BODY LENGTH2.275 INCHES NOMINAL
BODY HEIGHT3.700 INCHES NOMINAL
BODY WIDTH1.963 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.620 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.360 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.138 INCHES
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONZZ140.00 HERTZ AND ZZ200.00 HERTZ AND ZZ1.00 KILOHERTZ AND ZZ1.80 KILOHERTZ
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSZZ34.0 NOMINAL AND ZZ1.7 NOMINAL AND ZZ1.7 NOMINAL AND ZZ34.0 NOMINAL
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONZZ INDUCTANCE-CAPACITANCE