Part Details | RADIO FREQUENCY INTERFERENCE FILTER
5915-01-145-6071 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.
Alternate Parts: 1250 003, 142C547H01, 1250 003, 5915-01-145-6071, 01-145-6071, 5915011456071, 011456071
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 14, 1983 | 01-145-6071 | 00765 ( FILTER, RADIO FREQUENCY INTERFERENCE ) |
REFERENCE DRAWINGS & PICTURES
ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
Cross Reference | NSN 5915-01-145-6071
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 1250 003 | 18796 | MURATA ERIE NORTH AMERICA INCSTATE COLLEGE OPNS |
| 142C547H01 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS |
| 1250 003 | 33095 | SPECTRUM CONTROL, INC.DBA API TECHNOLOGIES |
Technical Data | NSN 5915-01-145-6071
| Characteristic | Specifications |
|---|---|
| SOURCE IMPEDANCE RATING PER FUNCTION | ZZ50.0 OHMS |
| LOAD IMPEDANCE PER FUNCTION | ZZ50.0 OHMS |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | BZZ200.0 VOLTS |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 BLANK |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 BLANK |
| MAXIMUM VOLTAGE DROP PER FUNCTION | BZZ2.0 VOLTS |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| OVERALL LENGTH | 1.202 INCHES NOMINAL |
| WIDTH ACROSS FLATS | 0.187 INCHES NOMINAL |
| BODY LENGTH | 0.309 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
| NOMINAL THREAD SIZE | 0.164 INCHES |
| FEATURES PROVIDED | NUT AND WASHER |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | ZZ INDUCTANCE-CAPACITANCE |
| MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
| FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | B0.0$$B0.1$$B1.0$$B10.0$$B100.0$$B1000.0 |
| FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | B3.0$$B20.0$$B40.0$$B60.0$$B80.0$$B80.0 |
| MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 400.0 VOLTS AT SEA LEVEL |
| OPERATING TEMP RANGE | -55.0 TO +85.0 DEG CELSIUS |
| BODY MATERIAL | METAL |