Part Details | BAND PASS FILTER
5915-01-158-2419 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).
Alternate Parts: 50460601, 504-606-01, 7330221, 733022-1, FX20075401, FX20-0754-01, 103820, 5915-01-158-2419, 01-158-2419, 5915011582419, 011582419
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUL 19, 1983 | 01-158-2419 | 00209 ( FILTER, BAND PASS ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
Cross Reference | NSN 5915-01-158-2419
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 504-606-01 | 05627 | APPLIED RESEARCH INC |
| 733022-1 | 05869 | RAYTHEON COMPANYDBA RAYTHEON |
| FX20-0754-01 | 57023 | SAN ANGELO CO INC |
| 103820 | 56216 | TELEDYNE WIRELESS, LLCDBA TELEDYNE MICROWAVE SOLUTIONS |
Technical Data | NSN 5915-01-158-2419
| Characteristic | Specifications |
|---|---|
| REFERENCE FREQUENCY PER FUNCTION | ZZ1.03 GIGAHERTZ |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 25.0 BLANK |
| FREQUENCY BAND WIDTH PER FUNCTION | ZZ1.02 GIGAHERTZ AND ZZ1.04 GIGAHERTZ |
| INPUT IMPEDANCE PER FUNCTION W/LOAD | ZZ50.0 OHMS |
| OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | ZZ50.0 OHMS |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.5 BLANK |
| VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | ZZ1.02 GIGAHERTZ AND ZZ1.04 GIGAHERTZ |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| OVERALL LENGTH | 2.890 INCHES NOMINAL |
| BODY LENGTH | 2.140 INCHES NOMINAL |
| BODY HEIGHT | 0.790 INCHES NOMINAL |
| BODY WIDTH | 1.840 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.140 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.515 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.375 INCHES NOMINAL |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | ZZ980.00 MEGAHERTZ AND ZZ1.02 GIGAHERTZ AND ZZ1.04 GIGAHERTZ AND ZZ1.05 GIGAHERTZ |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | ZZ25.0 MINIMUM AND ZZ1.6 MAXIMUM AND ZZ1.6 MAXIMUM AND ZZ25.0 MINIMUM |
| UNPACKAGED UNIT WEIGHT | 2.000 POUNDS |
| OPERATING TEMP RANGE | -40.0 TO +60.0 DEG CELSIUS |
| BODY MATERIAL | METAL |