Part Details | CARTRIDGE FUSE
5920-00-296-4164 A fuse in which the element is inclosed in a cylindrical body. The element may be renewable. The terminals may be of varying types. It may contain a visual indication that the fusible element is severed, and may also provide an audible alarm through auxiliary circuitry. For noncylindrical items, see FUSE, INCLOSED LINK.
Alternate Parts: F02D2200B, F02D2R00B, MS90078261, MS90078-26-1, RE28B124, 11003200, VBE860T2K, 5920-00-296-4164, 00-296-4164, 5920002964164, 002964164
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-296-4164 | 00248 ( FUSE, CARTRIDGE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5920-00-296-4164
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| F02D2200B | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| F02D2R00B | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MS90078-26-1 | 96906 | MILITARY STANDARDSPROMULGATED BY MILITARY DEPARTMENTS |
| RE28B124 | 80064 | NAVAL SHIP SYSTEMS COMMAND |
| 11003200 | 18778 | THALES COMPONENTS CORPORATION |
| VBE860T2K | H0203 | THALES NEDERLANDDBA THALES LAND & JOINT SYSTEMS |
Technical Data | NSN 5920-00-296-4164
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 1.250 INCHES NOMINAL |
| OVERALL DIAMETER | 0.250 INCHES NOMINAL |
| CONTINUOUS CURRENT RATING IN AMPS | 2.000 |
| MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 AC AND 250.0 DC |
| CIRCUIT OVER-CURRENT INTERRUPTION TYPE | TIME DELAY |
| CIRCUIT OVER-CURRENT INTERRUPTION DELAY TIME IN SECONDS | 6.0 300 PCT OF CURRENT RATING |
| INTERRUPTION INDICATOR METHOD | VISIBLE ELEMENT |
| TERMINAL SURFACE TREATMENT | SILVER PLATED |
| FEATURES PROVIDED | NONRENEWABLE FUSIBLE ELEMENT |