Part Details | EXTRACTOR POST FUSEHOLDER
5920-00-519-4274 A fuseholder in which the clips or contacts for electrical connection to the fuse are mounted in a tubular body or similar inclosure which surrounds the fuse. It generally contains a removable cap or knob. It includes in-the-line type and those designated as miniature type FUSEHOLDER (as modified).
Alternate Parts: 400219002, 4-00219-002, 276B502AAG5, 1002919PC4, 68548011, 685480-11, 1857208PC4, 5920-00-519-4274, 00-519-4274, 5920005194274, 005194274
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1961 | 00-519-4274 | 28909 ( FUSEHOLDER, EXTRACTOR POST ) |
REFERENCE DRAWINGS & PICTURES
PANEL MOUNTED TYPE
ONE HOLE MOUNTING
Cross Reference | NSN 5920-00-519-4274
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 4-00219-002 | 03848 | ARMA DIVAMBAC INDUSTRIES INC |
| 276B502AAG5 | 03497 | GENERAL ELECTRIC COOUTDOOR BREAKER BUSINESS SECTION |
| 1002919PC4 | 56232 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
| 685480-11 | 56232 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
| 1857208PC4 | 10001 | NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT |
Technical Data | NSN 5920-00-519-4274
| Characteristic | Specifications |
|---|---|
| FUSE ACCOMMODATION QUANTITY | 1 |
| CURRENT CARRYING RATING IN AMPS | 60.0 |
| VOLTAGE IN VOLTS | 250.0 |
| FUSE TERMINAL TYPE ACCOMMODATED | FERRULE |
| TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
| SCREW THREAD DIAMETER | 0.250 INCHES NOMINAL |
| SCREW THREAD QUANTITY PER INCH | 20.0 |
| CONTACT MATERIAL | BERYLLIUM COPPER |
| CONTACT SURFACE TREATMENT | ANY ACCEPTABLE |
| BODY STYLE | PANEL MOUNTED TYPE |
| OVERALL LENGTH | 5.844 INCHES MINIMUM AND 5.906 INCHES MAXIMUM |
| OVERALL DIAMETER | 2.907 INCHES MINIMUM AND 2.969 INCHES MAXIMUM |
| PANEL THICKNESS | 0.125 INCHES MAXIMUM |
| LENGTH FROM FRONT PROTRUSION TO MOUNTING SURFACE | 1.094 INCHES MAXIMUM |
| CAP DIAMETER | 1.594 INCHES MINIMUM AND 1.656 INCHES MAXIMUM |
| MOUNTING HOLE STYLE | 5 ONE HOLE MOUNTING |
| CENTER TO CENTER DISTANCE BETWEEN OUTSIDE MOUNTING HOLES ALONG LENGTH | 2.370 INCHES MINIMUM AND 2.380 INCHES MAXIMUM |
| BUSHING HOLE DIAMETER | 1.680 INCHES MINIMUM AND 1.717 INCHES MAXIMUM |
| MOUNTING HOLE QUANTITY | 2 |
| MOUNTING HOLE DIAMETER | 0.340 INCHES MINIMUM AND 0.353 INCHES MAXIMUM |
| ACCOMMODATED FUSE LENGTH | 3.000 INCHES NOMINAL |
| ACCOMMODATED FERRULE DIAMETER | 0.781 INCHES MINIMUM AND 0.843 INCHES MAXIMUM |
| INTERRUPTION INDICATOR METHOD | INCANDESCENT LAMP |
| ENVIRONMENTAL PROTECTION | ANY ACCEPTABLE |
| TERMINAL MATERIAL | COPPER, QQ-C-502 |
| TERMINAL SURFACE TREATMENT | G0012 ANY ACCEPTABLE |
| BODY MATERIAL | PLASTIC, MIL-P-14, TYPE MAI-60 |