Part Details | ENCLOSED LINK FUSE
5920-00-557-6101 A fuse in which the element is inclosed in a body of other than cylindrical shape. It may include visual indication that the fusible element is severed. For cylindrical items, see FUSE, CARTRIDGE. Excludes FUSE, OPEN LINK; and FUSE LINK, ELECTRICAL.
Alternate Parts: 67B1831400, 67B1831-400, ANL400, 10087152, 5920-00-557-6101, 00-557-6101, 5920005576101, 005576101
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-557-6101 | 00249 ( FUSE, ENCLOSED LINK ) |
REFERENCE DRAWINGS & PICTURES
SLOTTED LIMITER
Cross Reference | NSN 5920-00-557-6101
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 67B1831-400 | 97151 | AIR FORCE LIFECYCLE MANAGEMENTCENTER ELECTRONIC COMPONENTS |
| ANL400 | 71400 | COOPER BUSSMANN, LLCDBA COOPER BUSSMANN |
| 10087152 | A486G | NIMIKKEISTOKESKUS NCB FINLAND |
Technical Data | NSN 5920-00-557-6101
| Characteristic | Specifications |
|---|---|
| BODY STYLE | SLOTTED LIMITER |
| OVERALL LENGTH | 3.188 INCHES NOMINAL |
| TERMINAL LENGTH | 0.875 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.438 INCHES NOMINAL |
| OVERALL HEIGHT | 0.750 INCHES MAXIMUM |
| OVERALL WIDTH | 0.875 INCHES NOMINAL |
| MOUNTING SLOT WIDTH | 0.344 INCHES NOMINAL |
| TERMINAL WIDTH | 0.750 INCHES NOMINAL |
| TERMINAL THICKNESS | 0.095 INCHES NOMINAL |
| CONTINUOUS CURRENT RATING IN AMPS | 400.000 |
| MAXIMUM VOLTAGE RATING IN VOLTS | 32.0 AC AND 32.0 DC |
| CIRCUIT OVER-CURRENT INTERRUPTION TYPE | NORMAL INSTANTANEOUS |
| INTERRUPTION INDICATOR METHOD | VISIBLE ELEMENT |
| SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS | 10000.0 |
| TERMINAL SURFACE TREATMENT | SILVER PLATED |